13C50-0165 - Stationary Vertical Mixer V-Mix 280 Standard - March 2016
17
Greasing planetary tower top bearing
Lubrication points
Grease flange bearings
on the opening door system�
Grease universal joints on PTO drive shaft�
5.1.4 - CHANGING PLANETARY GEARBOX OIL
It is recommended to run the mixer for several minutes to warm the
oil before draining� Draining oil while it is hot avoid sludge depo-
siting�
1� Use SAE 80/90 gear oil or SAE 70/80 gear oil�
2� Check oil level daily�
3� Change oil for the first time after 100 hours of operation�
4� Thereafter, change the oil every 2000 hours of operation or at
least once a year, whichever occurs first�