17
Should the mixer is turning in clockwise direction, it is necessary to change the
connecting position of any of the two phases.
Production cylinder mixer, installed in appliances with built-in inverter, will rotate in
the counter clockwise direction regardless of the connecting position of either of
the phases.
After connecting the appliance to the electricity network, appropriately trained
electrician must also control the power consumption. The current must not exceed
the maximum allowed on the identification plate or sticker (see the section
GENERAL FEATURES AND SPECIFICATIONS).
Appliance with more than 2kW power should have fixed electrical connection.
Fuses can’t exceed manufacturer prescripted fuse power! (possible cause of fire)!
6 OPERATING THE APPLIANCE
The user operates the appliance standing in front of appliance. This position
allows user to handle the control panel, the safety switch and the water flow
regulation valve (shower).
The appliance must be always under users control during operation.
The control panel is used to display the status or the operation phase the machine
is in, to perform settings and to show messages and errors while producing ice
cream.
The safety switch is used to safely and securely switch of the electronics. The
electronics is switched off by pressing down the switch-off key in the normal
position and then depressing it. The switch will normally remain down and must be
pulled back up by hand to return to its normal position.
The shower is used for cleaning of the appliance.
SAFETY
SWITCH
CONTROL
PANNEL