137
Place the slider into the mixer;
insert the mixer into the cylinder:
Hold the mixer with both hands and place it very slowly into the cylinder. Place
the mixer by the edge of the cylinder so that the spade which has the slider
closest to the bottom of the cylinder is placed horizontally downwards, Slowly,
without spinning, push the thusly placed mixer towards the end of the cylinder.
When the mixer shaft is in bed, find the final position of the mixer in the bed of
the drive shaft by slowly spinning it in a clockwise direction.
close the door;
the proper installation of the blades on the mixer is checked by a TEST
RUN (see chapter MAINTENANCE OF THE APPLIANCE).
14.7 SETTING THE WATER REGULATION VALVE
The water regulation valve is preset to factory default values. These may
change due to possible shocks and vibrations during transportation.
In this case, the water regulation valve has to be reset properly by authorized
servicing personnel.
The water regulation valve functions properly when tepid water is discharged
from appliance during the operation of the compressor unit; the water flow stops
when the appliance stops. Water consumption increases if the temperature of
cooling water exceeds 18°C.