9
© Vallox Oy - All rights reserved
BEFORE BEGINNING MAINTENANCE
WORK
The safety switch automatically turns off the power when the
door of the unit is opened.
WARNING
Always disconnect the power plug before starting the
ventilation unit maintenance.
NOTE
The service space in front of the ventilation unit must be at
least 800 mm.
Opening and closing the doors
1. Turn the latches to open the upper door of the ventilation unit.
2. Lift the upper door off.
CAUTION
The door is heavy.
3. Open the lower door of the ventilation unit by undoing the
finger screws.
4. Lift the lower door off.
5. Close the doors in reverse order.
There are two unit models, left- (L) and right-handed (R). The
figure shows the right-handed model.
CHANGING THE FILTERS
When the maintenance reminder becomes activated, check the
cleanliness of the filters and replace them if required.
The Vallox ventilation unit has three air filters:
• Coarse filter for supply air filters insects, heavy pollen and
other relatively large foreign objects out of the outdoor air.
• Fine filter for supply air filters microscopic pollen and dust
particles out of the supply air.
• Coarse filter for extract air filters the extract air and keeps the
heat recovery cell clean.
The filter replacement interval depends on the ambient particle
concentration. It is recommended that the filters be replaced
every spring and autumn, or at the very least once a year.
NOTE
Using original Vallox filters ensures that the ventilation unit
remains in top condition, giving the best results. To select
and order filter packages, please go to: filters.vallox.com
To replace the filters:
1. Disconnect the ventilation unit from the mains electricity supply.
2. Open the upper door of the unit.
3. Remove the old filters (A, B, C) and discard them.
4. Install the new filters (A, B, C).
5. Close the door of the unit. Ensure that the safety switch catch
of the door is touching the safety switch, allowing the unit to
be turned on.
6. Plug the ventilation unit back into the mains.
The filters have now been successfully replaced.
MAINTENANCE
MAINTENANCE