INSTRUCTIONS FOR USE

2.

Instructions for using VALLOX TSK Multi 50/80

For indoor air to stay healthy and beneficial also for the structures of the dwelling, ventilation
has to be in operation continually. It is not advisable to stop ventilation even for longer
holidays, because it makes indoor air stuffy. Also, during the heating season indoor air
humidity may condense in the ducts and structures and therefore cause humidity damage.

2.2.  Selection of fan speed

Fan speed is selected by using a separate Simple Control speed selector or
Slim Line PTXPA SC cooker hood.

2.2.1. Speed 

selector

The speed selector can be used to select speeds 1, 2, 3 and 4:

1.     

Use during absence

. When the dwelling is empty, ventilation can temporarily be diminished.

2-3.  

Normal use

. In normal conditions air needs to be replaced once in two hours.

4.     

Boosted operation

. Cooking, bathing in the sauna or bathroom, drying clothes, using the

toilet, having guests, overheat or a similar situation may cause a need for higher than
normal ventilation.

If there is a cooker hood independent of the ventilation system in the dwelling, it is not
necessary to raise the speed of VALLOX Multi TSK 50/80 during cooking.

2.3. Post-heating

For most of the year, heat recovered from the air being extracted is enough to warm the cold
air coming from the outside to a suitable temperature. If the heat of extract air is not enough,
air coming from the outside may be heated further with a heating radiator in the unit (option).

2.1. Initial adjustment

The ventilation system works properly when air flows in the rooms have been measured and
adjusted with the valves in accordance with the planned values. 

After the initial adjustment, the

position of the ventilation valves must not be changed

, with the exception of the outlet valve with a

knob located on the ceiling of a sauna, which can be adjusted if needed. The initial adjustment
ensures that a sufficient amount of air is circulated and that extract air flow is always greater
than supply air flow, i.e. the dwelling is negatively pressured compared to outdoor air. If
the dwelling is positively pressured, air in the dwelling penetrates the outer envelope of the
building and between windows, which may cause humidity damage during the heating
season.

In normal conditions basic ventilation

, with a change of air every two hours, is sufficient in living

areas. Boosting is needed during for example sauna baths, cooking, clothes washing or
family parties.

Simple Control

Summary of Contents for TSK Multi 50 L

Page 1: ...MAINTENANCE MODELS VALLOX TSK MULTI 50 R VALLOX TSK MULTI 50 L VALLOX TSK MULTI 80 R VALLOX TSK MULTI 80 L SUPPLY AND EXTRACT AIR VENTILATION WITH HEAT RECOVERY TYPE TSK MULTI 50 3601 TSK MULTI 80 360...

Page 2: ...ter L or R after the name of the unit indicates whether the unit is left or right handed VALLOX TSK Multi 50 R VALLOX TSK Multi 50 L VALLOX TSK Multi 80 R VALLOX TSK Multi 80 L EVERYDAY QUICK GUIDE NO...

Page 3: ...tumn Dust mites thrive in indoor air if humidity exceeds 50 and if humidity stays at over 60 for a long time in winter water condenses in the cold structures of the house and mould starts to form The...

Page 4: ...dwelling it is not necessary to raise the speed of VALLOX Multi TSK 50 80 during cooking 2 3 Post heating For most of the year heat recovered from the air being extracted is enough to warm the cold a...

Page 5: ...xtract air may freeze in the heat recovery cell Freezing can be prevented by stopping the supply air fan or the unit can be equipped with a preheating resistor which is switched on as needed 2 6 1 Sto...

Page 6: ...ast every two years The fine filter D is not washable Clean it at the same time as the G3 class filters by vacuuming it with a brush nozzle When cleaning be careful not to break filter material To ens...

Page 7: ...trical quick connectors 1 of the fan assembly have to be unfastened The fan assembly can then be tilted sidewards 2 and pulled out through the maintenance door 3 3 4 Condensing water During the heatin...

Page 8: ...sistor see Section 2 6 Defrosting on page 5 You can turn the defrost thermostat clockwise In this case there will probably be no freezing but extract air can be too warm when going out The defrost the...

Page 9: ......