MAINTENANCE
FILTER CHANGE
The unit must be fully isolated from the mains power supply before all
maintenance and cleaning measures.
The filters must be checked for contamination, damage, and odours
once in every three months. If the filters are damp or mouldy, they must
be replaced immediately.
The Vallox Pureo TX unit is equipped with an ePM1 60% class filter on
the outdoor air side and an ePM10 60% class filter on the extract air side
as standard. If another filter is to be used in the unit, the settings of the
controller of the unit must be modified.
DANGER
Danger to life due to electric shock!
The technical data of the standard filter can be found in the table
below:
1. Open the lock and turn the handles counterclockwise to open the
doors.
2. Pull the lock to release the filter.
3. Remove the filter.
IMPORTANT
The air flow direction
of the filter must be
observed!
NOTE
Replacement air filters
are also available online
at filters.vallox.com