background image

11

Vallox

90

K

MC

© VALLOX • We reserve the right to make changes without prior notice.
What the units include can vary depending on the sales area.

MOUNTING INSTRUCTIONS

Insert the groove of

the fixing moulding (A)

at the upper of the

covering door to the

projections (B) at the

upper edge of the

ventilation unit’s door.
Press the magnets (C)

at the lower edge of

the covering door on

the door of the

ventilation unit.

VALLOX 90K MC
Mounting of covering door brackets

Lower edge

of covering door

620

Fixing

moulding (A)

Glue the magnet tape (C)

Screws

3.5*15

610

40

40

40

40

=

=

Cover the screw-heads with felt tape

Covering

door

598

B

A

B

A

C

Mounting

of covering door

Fasten the fixing

moulding (A) to the

covering door at the

point shown in the

figure, using screws

3.5*15 supplied with

the unit.
Cover the screw-heads

with felt tape.
Glue the magnet (C)

to the covering door

at the point shown in

the figure.

Summary of Contents for 90K MC Series

Page 1: ...90K MC R VALLOX 90K MC L Operating maintenance and technical instructions 10 1 2 8 4 5 3 11 12 6 7 9 Electrical connection 230V 50Hz 5 7A Degree of protection provided by enclosures IP34 Fans Extract...

Page 2: ...n it is advisable to contact Vallox Maintenance Adjustment of the relationship between supply and extract air This feature may be useful when adjusting air flows at the valves during mounting After th...

Page 3: ...s of filters A coarse filter A filters off insects heavy pollen and other dust An F7 class fine filter B filters off fine dust invisible to the eye Extract air is filtered with a coarse filter C By us...

Page 4: ...maintenance e g in autumn before the beginning of the heating season make sure that the condensing water outlet L in the bottom tank is not clogged You can check it by pouring a little water in the t...

Page 5: ...nd values Sound power level from the ventilation unit to supply air ducts by octave band LW dB Sound power level from the ventilation unit to extract air ducts by octave band LW dB ADJUSTMENT POSITION...

Page 6: ...fety switch SNO Phase voltage to supply air fan SFN Zero voltage to supply air fan EFL Phase voltage to extract air fan EFN Zero voltage to extract air fan FSO Input to fireplace switch FSI Fireplace...

Page 7: ...g a pipe to the water seal the water condensing from extract air can be led to a floor drain not directly to the drain The pipe must not rise after the water seal The unit has to be mounted horizontal...

Page 8: ...clude can vary depending on the sales area MOUNTING INSTRUCTIONS During mounting the unit rises 10 mm higher than the final height The lead in of electric wires can be done from both sides of the unit...

Page 9: ...e The preset voltages are as follows 2 5 V 5 V 7 5 V and 10 V Note Do not set control voltage so low that the fan does not start circa 1 5 V Sample adjustment of air flows Basic ventilation is adjuste...

Page 10: ...be a separate extract valve in the kitchen Basic extraction is not possible through the cooker hood when a VALLOX 90K MC unit is used The cooker hood is used for boosted smoke abatement An alternativ...

Page 11: ...r edge of the covering door on the door of the ventilation unit VALLOX 90K MC Mounting of covering door brackets Lower edge of covering door 620 Fixing moulding A Glue the magnet tape C Screws 3 5 15...