Low-energy ventilation unit  

with heat recovery

© Vallox
1.09.351 E
17.1.2019

1  Extract air fan 
2  Supply air fan
3  Post-heating radiator  

 

(electric 900 W)

4  Heat recovery cell
5  Outdoor air filter F7
6  Outdoor air filter G4
7  Extract air filter G4
8  Automatic summer/winter damper
9  Safety switch
10  Measurement outlets  

 

(behind an opening door)

11  Adjustment of the relationship  

 

between supply and extract air

12  Adjustment of supply air  

 

temperature and summer/ 

 

winter function

Code  

3524

Models

VALLOX 90K MC R

VALLOX 90K MC L

Operating, maintenance and technical instructions

10

1

2

8

4

5

3

11
12

6

7

9

Electrical connection  

230V 50Hz = 5.7A

Degree of protection provided by enclosures  IP34
Fans 

Extract air 

0.119 kW 0.9A   92dm

3

/s    50Pa 

direct current (DC)  Supply air 

0.119 kW 0.9A   75dm

3

/s    50Pa

Heat recovery  

 

Cross-counter flow heat recovery cell, 

h

> 80%

Heat recovery bypass 

Automatic

Electric post-heating unit 

900 W, 3.9 A

Fans           

Supply air 

G4 and F7 

 

Extract air 

G4

Weight 

 

52 kg

Ventilation control   

Cooker hood

TECHNICAL DATA

The figure shows the R model

Vallox

90

K

MC

The measurement outlets are 

located behind the machine 

plate. Detach the machine 

plate by pushing it to the left 

and pull the outlets out.

Summary of Contents for 90K MC Series

Page 1: ...90K MC R VALLOX 90K MC L Operating maintenance and technical instructions 10 1 2 8 4 5 3 11 12 6 7 9 Electrical connection 230V 50Hz 5 7A Degree of protection provided by enclosures IP34 Fans Extract...

Page 2: ...n it is advisable to contact Vallox Maintenance Adjustment of the relationship between supply and extract air This feature may be useful when adjusting air flows at the valves during mounting After th...

Page 3: ...s of filters A coarse filter A filters off insects heavy pollen and other dust An F7 class fine filter B filters off fine dust invisible to the eye Extract air is filtered with a coarse filter C By us...

Page 4: ...maintenance e g in autumn before the beginning of the heating season make sure that the condensing water outlet L in the bottom tank is not clogged You can check it by pouring a little water in the t...

Page 5: ...nd values Sound power level from the ventilation unit to supply air ducts by octave band LW dB Sound power level from the ventilation unit to extract air ducts by octave band LW dB ADJUSTMENT POSITION...

Page 6: ...fety switch SNO Phase voltage to supply air fan SFN Zero voltage to supply air fan EFL Phase voltage to extract air fan EFN Zero voltage to extract air fan FSO Input to fireplace switch FSI Fireplace...

Page 7: ...g a pipe to the water seal the water condensing from extract air can be led to a floor drain not directly to the drain The pipe must not rise after the water seal The unit has to be mounted horizontal...

Page 8: ...clude can vary depending on the sales area MOUNTING INSTRUCTIONS During mounting the unit rises 10 mm higher than the final height The lead in of electric wires can be done from both sides of the unit...

Page 9: ...e The preset voltages are as follows 2 5 V 5 V 7 5 V and 10 V Note Do not set control voltage so low that the fan does not start circa 1 5 V Sample adjustment of air flows Basic ventilation is adjuste...

Page 10: ...be a separate extract valve in the kitchen Basic extraction is not possible through the cooker hood when a VALLOX 90K MC unit is used The cooker hood is used for boosted smoke abatement An alternativ...

Page 11: ...r edge of the covering door on the door of the ventilation unit VALLOX 90K MC Mounting of covering door brackets Lower edge of covering door 620 Fixing moulding A Glue the magnet tape C Screws 3 5 15...

Page 12: ...12 Vallox 90K MC VALLOX We reserve the right to make changes without prior notice What the units include can vary depending on the sales area 1 09 351E 17 1 2019 PDF MOUNTING INSTRUCTIONS...

Reviews: