background image

VALLOX 75/95

9

MAINTENANCE INSTRUCTIONS

Filters and heat recovery cell.

The units are available in right and left handed
models. In the right handed model (model R)
outdoor air comes to the unit from the right side
of the centre line as shown in the instructions.

In the left handed model (model L) outdoor air
comes from the left side of the unit. The filters
and the heating radiator (D) change places
correspondingly.

In blocks of flats and terraced houses, the maintenance of the unit is taken
care of by a property maintenance company or the user, depending on the
contract.

Before starting maintenance activities, stop the machine either at the ON/OFF switch or by removing the
fuse from the fuse panel of the dwelling. The safety switch also turns the unit off when the door is opened.

FILTERS

Outdoor air is filtered in the unit with two types of filters. A G3 class coarse filter(A) filters
off insects, heavy pollen and other dust. A F7 class fine filter (B) filtersoff fine, invisible dust.
Extract air is filtered with similar G3 class filters as outsideair.

Clean the coarse filter (A) when needed for example by washing them 2 to 4 times a year
(and more often if needed). Wash a coarse filter with +25…30 

°

C warm water and washing-

up liquid, pressing it smoothly. Do not handle the filters with force.When washing is done
properly, filters stand cleaning 4…5 times. In otherwords, you have to 

replace them at least every

two years

 or when needed.

The fine filter (B) is not washable. Clean it at the same time as the coarse filters,using the
brush nozzle of a vacuum cleaner. When cleaning, be careful no tobreak filter material. 

To

ensure good supply air quality

, replace the filter from every six months toyear (more often if needed)

depending on local air quality. It is recommended to replace filters in autumn. This way the
filters stay cleaner through the winter and can effectivelyfilter off dust in the following spring.

In connection with the cleaning of the filters, it is also advisable to check the cleanliness of
theheat recovery cell (C) every two years or so. Grab the ears at the ends of the cell and
pull thecell out of the unit. If the cell is contaminated, soak it in a solution of water and
washing-upliquid. Rinse the cell clean with a jet of water. When all the water has drained
from betweenthe laminas, push the cell back so that the sealings next to the sliding surfaces
are in place andthe "up" sticker at the end of the cell points to the corner next to the upper
support.

In addition, check in autumn and spring the position of the summer / winter damper and
theleaving of condensing water from the unit as well as the position of the post-heating
radiator thermostat.

Filter guard Vallox 75/95 (option)

VALLOX 75/95 can be equipped with an optional filter guard. The filter guard indicator
lights up at speeds 3 and 4 when the filters are clean; this is normal and does not call for
any maintenance activities. If the indicator does not light up at speed 4, the pressure over
the finefilter differs from the factory setting. When needed, an expert may change the setpoint.

If the filter guard symbol already lights up at fan speed 1 or 2, the filters need cleaning

. If they are clean,

the lighting up may be caused by a clogged up dense mosquito net installed against mounting
instructions in the external grille or by the closing of the supply air valves in the rooms.

A

B

A

Filter guard indicator lamp

Summary of Contents for 75

Page 1: ...INSTRUCTIONS FOR USE AND MAINTENANCE 1 09 292E 13 02 07 VALLOX For blocks of flats terraced houses and detached houses Supply and extract air ventilation with heat recovery Type 3510...

Page 2: ...rying fa cilities during these activities Sleeping Ventilation in a bedroom has to be suffi cient throughout the night The level is cor rect when air does not smell fusty when you enter the room in th...

Page 3: ...thrive in indoor air if humidity exceeds 50 and if humidity stays at over 60 for a long time in winter water condenses in the cold structures of the house and mould starts to form The recommended maxi...

Page 4: ...ered before taking it in to the dwelling A coarse filter first removes the biggest litter particles thereby preventing the system from getting dirty After that air passes through a fine filter which c...

Page 5: ...during for example sauna baths cooking clothes washing or family parties If the user does not know the measured air flows the adjacent table shows approximate extract air flows as well as the total e...

Page 6: ...toilet guests excess heat and large dwellings Speed 4 This boosting position is used as needed for example during cooking parties and hot weathers Cooking Open the flap of the cooker hood during cooki...

Page 7: ...g supply air The temperature of supply air is adjusted at the thermostat regulator located inside the unit Adjustment range of temperature is approximately 0 25 C It is advisable to set the thermostat...

Page 8: ...at at 0 C position so that the radiator will not heat If needed the setpoint value of the water radiator thermostat shall also be reduced Defrosting Water condensing from extract air may freeze in the...

Page 9: ...filter material To ensure good supply air quality replace the filter from every six months toyear more often if needed depending on local air quality It is recommended to replace filters in autumn Thi...

Page 10: ...amper in the VKL model Unfastening and fastening of the thermostat part of the self actuated valve A B C Put the hook on the edge of the damper Y under the back edge of the fastening collar K of the f...

Page 11: ...he ceiling or the wall caused by the flow coming from the valve Cooker hood connected to the ventilation unit The most important object of maintenance is the grease filter To ensure sufficient absorpt...

Page 12: ...outdoor temperatures no humidity no freezing you can move the sensor further away from the cell An expert may also adjust the thermostat in the connection box by turning its spindle clockwise to 10 C...

Page 13: ......

Reviews: