background image

VALLOX 70 COMPACT

© VALLOX • We reserve the right to make changes without prior notification.
What the units include can vary depending on the sales area.

VENTILATION ADJUSTMENT

4

HEAT RECOVERY BYPASS

FIREPLACE SWITCH FUNCTION (option)

Speed selector

Cooker hood PTXP/I 130

Speed selector

The VALLOX 70 COMPACT delivery includes a four-step switch. The flush-mounted switch
can be mounted in a standard instrument box. The switch can be used to select four of
the seven speeds for the unit. The speeds selected for the unit are 1, 2, 3 and 4. An
expert can select different speeds at the transformer of the unit.

Control with a cooker hood

When desired, cooking smoke abatement can be connected directly to VALLOX 70
COMPACT and controlled with cooker hood VALLOX PTXP / I 130.

Winter use

In winter use the heat recovery cell of VALLOX COMPACT recovers heat
from the air leaving the dwelling and uses it to heat the air coming from the
outside.

Summer use

The heat recovery cell is bypassed in VALLOX 70 COMPACT with an in-built damper.
In the summer position air flow through the cell is prevented, and heat recovery
bypass is activated.

If the unit has been equipped with a fireplace switch (timer), it can be used to stop
the extract air fan for a certain period, such as 15 minutes, producing overpressure
in the ventilation zone. This makes it easier to light the fireplace, for instance.
The situation will normalise in a while, after the functions stops.

Note! The starting of the extract air fan may weaken draught in the fireplace.

Summary of Contents for 70 COMPACT R/L

Page 1: ...unction Filter guard Heat recovery Heat recovery bypass Post heating Preheating option Filters Weight Service switch Power adjustment Input power and data Options Fans Supply air Extract air 105 W 56...

Page 2: ...tdoor air filter F7 1 2 3 5 6 4 7 8 9 10 Outdoor air filter G4 Extract air filter G4 Summer winter damper Summer winter damper lock Air flow measuring outlets The picture shows VALLOX 70K COMPACT mode...

Page 3: ...0 50 150 200 250 Pa S E S E 2 S 1 3 SFP kW m s 2 0 1 1 2 1 3 1 1 2 59 66 70 72 74 76 76 80 44 50 55 57 60 64 67 71 35 41 46 48 50 53 55 58 22 29 34 36 38 40 43 46 19 25 30 33 35 39 42 43 14 17 22 25 2...

Page 4: ...batement can be connected directly to VALLOX 70 COMPACT and controlled with cooker hood VALLOX PTXP I 130 Winter use In winter use the heat recovery cell of VALLOX COMPACT recovers heat from the air l...

Page 5: ...ed inside the unit The tubular preheating radiator is connected to two overheat protectors One of the overheat protectors is automatically resetting type BTS and the other is a cut off one type BTC cu...

Page 6: ...ATING RADIATOR SILENCER SILENCER In VALLOX 70K Compact model extract air through cooker hood cooker hood attached to the unit H PLUG DISTRIBUTION PANEL VALLOX 70K Compact 230 V 50HZ 10 A EL FIREPLASE...

Page 7: ...ezing of the HR cell The fan starts automatically as soon as the risk of freezing has passed The threshold temperature of freezing risk can be set at thermostat T2 Fireplace switch function The unit c...

Page 8: ...With preheating radiator T1 Post heating radiator regulating thermostat 0 40 C T2 Defrost thermostat 0 10 C SV Filter guard option ML Filter guard indicator light TAK Fireplace switch option For inst...

Page 9: ...MIN MIN MAX MAX M A X 1 2 1 2 10A 3 x 1 5 S 4 x 1 5 S 5 x 1 5 S MAX 230 V MIN 230 V 1 2 230 V 6 x 0 5 N L N VALLOX 70 Compact L N III I I L 1 I 1 2 N DISTRIBUTION PANEL REMOTE MONITORING OPERATION ST...

Page 10: ...Post heating radiator EL Preheating radiator T1 Post heating radiator regulating thermostat 0 40 C T2 Defrost thermostat 0 10 C SV Filter guard option There is no wire between JL in unit with filter c...

Page 11: ...bottom of the ventilation unit and fix the hood with the knurled head nut F It is possible to adjust the hood by 10 mm in depth as compared to the ventilation unit Lower edge of bracket 10 During mou...

Page 12: ...g water the water seal may get dry in 1 to 4 weeks Normally to the floor drain with a long water seal A long water seal ensures soundlessness for a long time Straight to the floor drain without a wate...

Reviews: