- 15 -
to holding the centering seat for the blade
upward (fig. E1)
4 Open the protective cover and insert the
blade, paying attention to the direction of
rotation (fig. E2). The arrow on the blade
must match that printed on the machine.
5 Insert the upper flange (fig. E3) by centering
the molded wall of the blade holder shaft.
6 Screw the fixing bolt with the relative washer
(fig. E4).
7 Tighten the bolt with the key no. 20 to secure
the screw and key nr.21 to lock the rotation
(fig.E5).
8 Carefully check that the blade guard returns
to rest and that it is working properly
9 Check that the blade rotates freely without
irregularity
10 Perform a blank operation test.
TRANSPORT
Always use the packaging or case when tran-
sporting the tool; this will protect it from impact,
dust and humidity which can compromise
normal operation.
MOVING
Grip the tool by the hand grip and after use wait
for it to stop completely before putting it down.
STARTING UP
When choosing where to use the electrical tool,
the following should be considered:
- that the place is not damp and is protected
from the elements.
- that there should be a large operational area
free from obstacles.
- that there is good lighting and sufficient air
exchange.
- that it needs to be used close to the general
differential switch.
- that the power supply system is earthed and
conforms to the standards (only if the electrical
tool is class 1, which is equipped with a plug
with earth cable).
- that the room temperature should be between
10° and 35° C.
- that the environment is not in a flammable/
explosive atmosphere.
- that there is a sawdust vacuum fitted with a
flexible hose.
GUIDE SET SQUARE ADJUSTMENT (pos.11)
Insert the guide set square in the guide panel
(pos.3) and tighten with the handwheel (pos.12).
Adjust the distance by observing the graduated
scale on it.
For cutting wide panels do not assemble the
guide set square but use a set square made with
a strip of wood as illustrated in fig.D.
ASSEMBLING THE CHIP VACUUM PIPE (fig.G
not supplied)
Insert the adaptor (pos. 19 fig. A) into the chip
opening (pos. 18 Fig. A) and connect the electri-
cal tool to a vacuum device for cutting residuals
(e.g. chip vacuum cleaner) using a flexible hose.
Insert the piping in the socket (pos.18) of the
tool’s casing. For the type suitable for the work,
ask your retailer.
ASSEMBLING BATTERIES FOR LASER INDICA-
TOR (where fitted) OR FOR LIGHTING (where
fitted)
Purchase batteries and install them in the battery
compartment according to the attached instruc-
tions respecting the polarity.
STARTING AND STOPPING
!
!
IMPORTANT! Before starting the electrical
tool, it is compulsory to wear all the personal
protective equipment (not supplied, see the
Safety instructions).
!
!
IMPORTANT! Make sure nobody is ap-
proaching the working area while the tool is
running. Keep safety distance from all moving
parts and from the cutting area.
!
!
IMPORTANT! The motor and the blade
continue to run for a few seconds after the tool
is switched off. During this time, these parts
must not be touched. Serious injury hazard!
Before starting the machine check the integrity
of all the components and that all the bolts and
couplings are tight.
Starting
1) Plug the tool into the power supply (pos.8).
2) Grip the rear hand grip (pos.5) and the front
hand grip (pos.4) firmly without pressing the
switch (fig.C).
3) Press the safety button (pos.7) and the switch
button (pos.6) in sequence. The switch is a
‘maintained action’ switch so the electrical tool
will stay on when you keep the switch pressed.