2) Bring the selector (2) into the “µA –mA” sector 

always starting from mA.

3) Take the measurement.

CURRENT MEASUREMENT UP TO 10A

This tester is not designed for making alter-

nating current measurements.

!

!

Warning!  With  the  socket  10A(5)  never 

exceed the limit of 10A

!

!

1) Connect the red probe to the 10A jack (5) 

and the black one to the “COM” jack (3).

2) Turn the dial (2) to the “10A” selection.

3) Take the measurement.

Warning: the tester is protected by a fuse that 

could intervene in case of exceeding 10A.

RESISTANCE MEASUREMENT

1) Connect the red probe to the “VΩ” jack (4) 

and the black one to the “COM” jack (3).

2) Turn the dial (2) to the “Ω” on the desired scale.

3) Take the measurement.

WARNING: The circuit must always be de-

energised when taking a resistance measu-

rement. Never connect the test leads to a 

voltage source; this is dangerous and could 

also damage the tool.

CONTINUITY TESTS

!

!

WARNING: The circuit on which you want 

to run the diode test must be de-energised to 

avoid seriously damaging the tool.

1) Connect the red probe to the “VΩ” jack (4) 

and the black one to the “COM” jack (3).

2) Turn the dial (2) to DIODE 

 , BUZZER 

3) Take the measurement.

You will hear a noise and the LED(6) lights up if 

there is continuity in the circuit.

DIODE TEST

!

!

WARNING: The circuit on which you want 

to run the diode test must be de-energised to 

avoid seriously damaging the tool.

1) Connect the red probe to the “VΩ” jack (4) 

and the black one to the “COM” jack (3).

2) Turn the dial (2) to DIODE 

 , BUZZER 

3) Take the measurement; connect the test leads 

to the poles of the diode to be tested. Read the 

voltage drop directly on the display in mV. If the 

connection is inverted or the diode junction is 

open, the display will read “I”.

SQUARE WAVE GENERATOR (50Hz)

1) Connect the red probe to the socket (4) “VΩ” 

and the black one to the “COM” (3).

2) Turn the switch (2) in the SQUARE WAVE 

 sector.

Attention this is a signal output. There is no 

protection for the short circuit.

BATTERY REPLACEMENT

Make sure the tool is switched off when installing 

the battery (function dial (2) in OFF position). 

This will prevent damage to the multimeter if the 

battery is incorrectly connected.

Replace the battery when the battery symbol  

  

  appears on the display. To replace the 

battery, follow the instructions below:

- using a screwdriver, remove the rear battery 

compartment cover (16).

- remove the battery and replace it.

- close the compartment cover and tighten the 

screws.

FUSE REPLACEMENT

The 10A socket (5) is protected against overload 

by a fuse (15) inside the unit.

In case of intervention, reduce current and re-

place the fuse with one with the same features 

(not supplied).

To replace the following guidelines:

- Remove the protective case (7)

- With the use of a screwdriver, remove the rear 

cover (8)

- Remove the fuse (11) and replace it with one 

of equal value

- Close the cover and retighten the screws.

- Mount the protective case.

Summary of Contents for S800146

Page 1: ...istruzioni di sicurezza e le istruzioni d uso fornite WARNING Before using the product read and understand the supplied safety instructions and operating instructions Tester digitale ISTRUZIONI D USO...

Page 2: ...2...

Page 3: ...3...

Page 4: ...isoluzione Resolution 200 mV 0 5 rdg 2dgt 0 1 mV 2 V 1 mV 20 V 10 mV 200 V 100 mV 600 V 0 8 rdg 2dgt 1 V MISURAZIONE TENSIONE IN CORRENTE ALTERNATA V MEASURING ALTERNATING CURRENT VOLTAGE V Scala Scal...

Page 5: ...ibility that the product cited there complies with the essential health and safety requirements contained in the following European directives 2004 108 EC Persona autorizzata a costituire il fascicolo...

Page 6: ...ERVIZIO Nel luogo che utilizzerete lo strumento elettrico opportuno considerare che la zona non sia umida e sia al riparo dagli agenti atmosferici che attorno sia prevista un ampia zona opera tiva lib...

Page 7: ...iodinondeveessereintensione per non provocare gravi danni allo strumento 1 Collegate la sonda rossa alla presa 4 V e quella nera alla presa COM 3 2 Portate il selettore 2 nel settore DIODO CICALINA 3...

Page 8: ...di anomalie diverse da quelle indicate portatelo presso un centro di assistenza autorizzato esibendo la prova di acquisto e richiedendo ricambi originali Fate sempre riferimento alle informazioni rip...

Page 9: ...rea is not damp and is sheltered from the weather that the working area is sufficiently large and free from obstacles that the area is well lit that the ambient temperature is between the values liste...

Page 10: ...iously damaging the tool 1 Connect the red probe to the V jack 4 and the black one to the COM jack 3 2 Turn the dial 2 to DIODE BUZZER 3 Take the measurement connect the test leads to the poles of the...

Page 11: ...ctly after you have carried out the above ope rations or in the event of faults other than those described above take it to an authorised service centre showing proof of purchase and ask for original...

Page 12: ......

Reviews: