202
Thermo G
2 Technical data
2.2
Gas pressure regulator
Table 202 Technical data gas pressure regulator
2.3
Fuel
ATTENTION:
The heater may only be operated using natural gas
(CNG).
As fuel natural gas (CNG) with a minimum methane
content of 95 % is used.
If natural gas with a less methane content is used (natural
gas of class L), the CO
2
level must be adjusted according
to section 7.6.2 in chapter 7.
The max. oil content of the gas is 10 mg/m
3
.
2.4
Circulating pump
All desired information about the Valeo circulation pumps
can be found under www.valeo-thermalbus.com/eu_en/
Products/Pumps.
Gas pressure regulator
Test certificate
ECE R110, R10.04
Kind of gas
Natural gas (CNG) class H/L
Permissible oil content in gas
< 10 mg/m³
Input pressure
5 ... 220 bar
Output pressure
-0.25 ... -2.5 mbar
Pressure 1st stage
1.8 ... 3.5 bar
Pressure 2nd stage
0.65 ... 0.75 bar
Operating temperature
-40 ... +120°C
Sorage temperature
-40 ... +100°C
Rated voltage
24 V
Nominal coil power at rated voltage (2x)
24 W
Operating voltage range
20 ... 30 V
Dimensions
(tolerance
±
3 mm)
L 150 mm
W 130 mm
H 170 mm
Weight
1.7 kg