Rooftop Air Conditioning System Citysphere
Page 66
5.5.
Additional control panel functions
To be able to check all options of the system independent of temperatures, there is a test mode and a
visualization mode.
There is a parameter mode for an individual configuration of the control panel.
5.5.1. Test mode
NOTE
To avoid stress to the vehicle batteries, the test mode should only be run
with the vehicle engine running. Operation with the engine off is only
advisable when checking the fan.
At ambient temperatures below 17 °C the system may only be operated
restricted in the cooling operation:
IMPORTANT
Non-compliance may lead to damage of the compressor.
Operating
To get to the test mode you have to press the button
for a few seconds until the display
displays.
The password for access to the test mode is
. You enter the password by pressing the buttons
and
. To confirm the password, press the
button.
If you entered a wrong password, the temperature-setpoint-difference will be displayed again. If the entry
was correct, you can switch with the buttons
and
from outputs
to inputs
, by pressing
you will come to the corresponding menu.
To leave the test mode, the button
has to be pressed. To select the desired inputs/outputs, press the
buttons
and
and the button
.
Temperature
Description
Below 5 °C
No cooling operation permissible
Between 5 °C and 12 °C
Maximum operating time 3 minutes
Between 13 °C and 17 °C
Maximum operating time 15 minutes
Summary of Contents for CITYSPHERE