Rooftop Air Conditioning System Citysphere
Page 64
– Connect fan plug and secure with cable tape against chafing.
– Fasten intake air grille.
4.11.
Mount hood
– Check air filter for correct fit..
– After hood installation plug in the electrical connector of the condenser fan. Pull the cable as far as
possible to the right side facing the direction of travel. Secure the condenser fan cable using a cable
clamp to the right partition wall to avoid a collision of the cable with the fan wheel during operation.
– Insert the condenser fan and position the grid and the 4 attaching screws. After that secure the hood with
the 7 flathead screws. Finally tighten all screws.
– Condenser fan: 4 Nm (Torx30
– Hood
: 3 Nm (slotted)
Fig. 4.20
Fig. 4.21
Air filter