![Valcourt Waterloo Installation And Operation Manual Download Page 58](http://html1.mh-extra.com/html/valcourt/waterloo/waterloo_installation-and-operation-manual_850449058.webp)
58
FP15 & FP15A Waterloo - Installation and Operation Manual
7.6.4
Offset Chimney Installation
TABLE 2 - MINIMUM SYSTEM HEIGHT WHEN USING ELBOWS
Fireplace model
WATERLOO
Chimney model
All models (see
TABLE 3)
Vertical installation
15 ft. (4.6 m)
Two (2) elbows
15 ft. (4.6 m)
Four (4) elbows
17 ft. (5.2 m)
After reaching the location requiring the elbow, proceed as follows:
1.
To insure a good draft, it is recommended, to have a length of 18 inches (457 mm) from the top of the
unit to the first offset. Install the first elbow; turn it in the required direction. Secure it to the chimney
according to the chimney manufacturer’s instructions. In many cases, it is recommended to secure
connections with three (3) ½" (12 mm) metal screws.
2.
Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together
according to the chimney manufacturer’s instructions. In many cases, it is recommended to use three
(3) ½" (12 mm) metal screws. If the offset length is made of two (2) chimney lengths or more, many
chimney manufacturers may require that you use an offset or roof support halfway up the offset. If
penetrating a wall, install a wall radiation shield supplied by the chimney manufacturer.
3.
Use another elbow to turn the
chimney
vertically. Secure the elbow.
4.
Use a plumb bob to line up the centre of the hole. Cut a hole for the chimney in the ceiling/floor. Frame
this hole as described previously.
5.
From below, install a firestop supplied by the chimney manufacturer.
6.
A support must be used on the first 15' section (4.6 m).
7.
Continue with the regular installation.
WARNING
•
IN EVERY CASE, THE CHIMNEY MUST START WITH A 8'' DIAMETER
ANCHOR PLATE SECURED TO THE FIREPLACE. (SOLD SEPARATELY).
•
IF THE MALE NOZZLE (A) OF THE ANCHOR PLATE EXCEEDS 2" (51
MM) IN LENGTH (SEE IMAGE BELOW), IT SHALL BE CUT ABOVE
THE LIFTING HOOKS WELDED TO THE INSIDE OF THE FLUE OUTLET
SO THAT THE ANCHOR PLATE RESTS PERFECTLY ON TOP OF THE
FIREPLACE.
Summary of Contents for Waterloo
Page 2: ...2 FP15 FP15A Waterloo Installation and Operation Manual ...
Page 11: ...FP15 FP15A Waterloo Installation and Operation Manual 11 2 3 Measurements FP15 ...
Page 12: ...12 FP15 FP15A Waterloo Installation and Operation Manual ...
Page 13: ...FP15 FP15A Waterloo Installation and Operation Manual 13 2 4 Measurements FP15A ...
Page 14: ...14 FP15 FP15A Waterloo Installation and Operation Manual ...
Page 78: ...78 FP15 FP15A Waterloo Installation and Operation Manual ...
Page 88: ......