11
INSTALLATION:
The chimney must be relined with a stainless steel liner model Tubinox or Projet SS or any other listed
liner or flexible liner to ULC-S635, ULC-S640 or UL777 of the same diameter as the outlet of the
fireplace.
For connection at 45 angle, a special connector (BISPMA for the 7 in. chimney) must be used to connect
the liner to the insulated chimney. For connection at 30, use the BISPMA30 connectors.
Follow these steps:
1. Position the fireplace in its location. Temporarily install the ASHT+ elbow on the top of the fireplace and,
using a level, mark with an oval the location where the flue liner will enter the masonry chimney.
2. In the middle of the oval, drill a hole in the masonry chimney at 45 or 30.
3. Increase the size of the hole until a 45 or 30 Tubinox liner elbow can be easily slipped through.
4. Slide the liner down from the top of the masonry chimney until you reach the hole level.
5. Slip through the hole a 45 or 30 liner elbow and connect it to the liner.
6. Add a small liner section to the liner elbow which will allow the liner to extend at least 12” (measured at
the top of the liner) from the masonry chimney.
7. Seal the opening around the liner with high temperature refractory cement.
8. The next steps must be done in the following order:
8.1 Select the ASHT+ length that will fit between the elbow and the liner so that it will slide at least 2”
over the liner section. (You may need to cut the liner for a better fit.)
8.2 Take that section and the BISPMA (BISPMA30) cover and slide it over the line. Make sure you have
enough opening to be able to install the ASHT+ elbow without difficulty.
8.3 Install the 45 or 30 elbow on the fireplace.
8.4 Slide the length section back down on the elbow and twist lock the two together.
8.5 Pull the cover down over the length and install the insulation pad over the liner; be careful to cover the
liner completely.
8.6 Slide back the cover over the insulation and fix it in place using the 3 screws supplied.
Summary of Contents for Montcalm FP6
Page 9: ...9 Figure 5 Hearth Extension Installation ...
Page 12: ...12 Figure 6 Installation Security Chimney Adaptor Masonry Chimney ...
Page 15: ...15 Figure 7 Straight Chimney Installation Figure 8 Chimney with Elbows Installation ...
Page 16: ...16 Figure 9 Exterior Chimney Installation Figure 10 Isolated Chase Installation ...
Page 18: ...18 Figure 12 Chimney Enclosure ...
Page 19: ...19 Figure 13 Mantel Positioning ...
Page 20: ...20 Figure 14 Installation of Fireplace Facing ...
Page 24: ...24 Figure 15 Replacing Montcalm Firestones ...