Valcourt FG00001 Installation Instructions Manual Download Page 48

Page 48

Installation Manual - L48

ENGLISH

6.2  Wiring Diagram 

Notes:

 

• 
Connect wir

es in junction box on the

 

left side of the fir

eplace to house power

 

using the supplied wir

e nuts.

• 
Replacement wir

e must be of the same

 

size and type of insulation as original

 

• 
The appliance must be electrically

 

connected and gr

ounded in accor

dance

 

with local codes or

, in the absence

 

of local codes, with the curr

ent NFP

A

 

70-National Electric Code or CSA

 

C22.1-canadian Electrical Code.

 

• 
Label all wir

es prior to disconnectlon

 

when servicing contr

ols. W

iring err

ors
 

can cause impr

oper and danger

ous
 

operation. Certify pr

oper operation after

 

servicing.

ORANGE

PILO

T

GAS CONTROL VALVE

ORANGE GREEN

YELLOW

WHITE

OR

BLACK

BLACK

WHITE

BLOWE

R

E

S

U

F

BLACK

WHITE

GREEN

POWER CORD

TO

 JUNCTION

BO
X

LOOP

TO

 LIGHTS

E

V

E

E

L

S

USER INTERFACE/

BATTERY HOLDER

ORANGE

WHITE

Summary of Contents for FG00001

Page 1: ...our gas supplier from a neighbor s phone Follow the gas supplier s instructions Ifyoucannotreachyourgassupplier callthefiredepartment Installation and service must be performed by a qualified installe...

Page 2: ......

Page 3: ...Page 3 Installation Manual L48 ENGLISH To reduce the risk of fire follow the installation instructions in this manual...

Page 4: ...e Installation 16 3 1 Safety Information 16 3 2 Appliance Location 16 3 3 Framing Clearances and Mantle 17 3 4 Finishing 25 3 5 Installing a television above a fireplace 27 4 Venting installation 28 4...

Page 5: ...d Glass Media Installation 50 7 1 Screen barrier and glass door removal 50 7 2 Glass Placement 51 7 3 Final Steps 52 8 Optional Traditional Gravity Hot Air Distribution Kit Installation AC04367 53 9 O...

Page 6: ...Page 6 Installation Manual L48 ENGLISH CERTIFICATION PLATE...

Page 7: ...viduals out of the room and away from hot surfaces 4 For appliances requiring a barrier as determined under Clause 5 15 4 A barrier designed to reduce the risk of burns from the hot viewing glass is p...

Page 8: ...in which the appliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting...

Page 9: ...her low areas Stay out until firefighters declare them to be safe Use your neighbor s phone and call a trained Propane Gas service person and the fire department Even though you may not continue to sm...

Page 10: ...an area where the conditions are such that you may not detect the odor if there has been a leak of Propane Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is...

Page 11: ...local codes including permits and inspections The fireplace when installed must be electrically grounded in accordance with local codes or in absence of local codes with the National Electric Code AN...

Page 12: ...here the fireplace is to be installed and whether optional accessories are desired Gas supply piping electrical connections and venting should also be planned at this time Refer to the framing section...

Page 13: ...Supply Pressures inches water column 11 0 4 5 Manifold Gas Supply Pressures inches water column 10 0 3 5 Burner orifice 50 DMS 1 95 mm 31 DMS 3 50 mm Efficiency 60 06 61 77 Air Shutter Opening Fully O...

Page 14: ...ocal hardware store Door Removal Tool attached to fireplace 1x AA Battery 4x AAA Battery 3x Wall Spacer attached to fireplace 1x Cover Plate Battery Box 1x Remote 1x Junction Box Cover 1x Duplex Recep...

Page 15: ...375mm 48 1219mm 12 7 8 325mm 58 1 4 1479mm L48 F 2021 FABRICANT DE PO LES INTERNATIONAL INC TOUS DROITS RESE O 5 130mm O 8 206mm 76 7 8 1951mm 21 3 8 544mm 7 1 8 180mm 12 3 8 314mm 30 1 2 776mm 52 1 4...

Page 16: ...ATION ISLAND INSTALLATION CABINET INSTALLATION CORNER INSTALLATION ANGLED CORNER INSTALLATION NOTE Island and Room Divider installation is possible as long as the horizontal portion of the vent system...

Page 17: ...uld be installed in the chase as per regional codes for the rest of the home Additionally in regions where cold air infiltration may be an issue the inside surfaces may be sheet rocked and taped or an...

Page 18: ...sion A includes a 24 inch clearance for framing standoffs on fireplace After installing fireplace into framing the non combustible board must cover the 24 inch opening above the fireplace NON COMBUSTI...

Page 19: ...5 F 26 3 3 8 G 24 1 3 4 H 22 0 This fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained Fireplace...

Page 20: ...A 4 102mm 66 TO 84 57 3 16 1453mm MIN 19 3 4 502mm 10 15 16 278mm 45 3 16 1148mm MIN FRAMING HEADER NON COMBUSTIBLE NON COMBUSTIBLE PANNEL AC04370 KIT A RATION DE L ENCEINTE NOTE COMBUSTIBLE MATERIALS...

Page 21: ...ing should be positioned to accommodate wall covering and fireplace facing material The fireplace framing should be constructed of metal studs CAUTION Measure fireplace dimensions and verify framing m...

Page 22: ...61 cm 24 in 61 cm E Clearances to unventilated soffit 12 in 30 cm 12 in 30 cm F Clearance to outside corner 6 in 15 cm 6 in 15 cm G Clearance to inside corner 9 in 23 cm 9 in 23 cm H Clearance to eac...

Page 23: ...r finished face when setting the depth of the fireplace 3 Secure the two framing brackets and hand bend them into a V shape as shown Secure with 10 x 1 2 inch hex head screws A B C D DETAIL A A 4 Loca...

Page 24: ...ing material flush or 1 2 in set back depths OR 8 Attach three middle mount framing brackets to the top front edge of the fireplace These brackets support the non combustible board above the fireplace...

Page 25: ...reen topping mud sand and prep for painting When using paint or lacquer to finish the mantel the paint or lacquer must be heat resistant to prevent discolouration A full single sheet of non combustibl...

Page 26: ...not be covered or blocked MOUNTING BRACKETS INSTALLED FLUSH TO THE FIREPLACE FACING NON COMBUSTIBLE BOARD INSTALLED ON THE FIREPLACE FACING 2 X 4 HEADER NON COMBUSTIBLE BOARD FINISHED WALL COMBUSTIBL...

Page 27: ...heat source If you install a television above this fireplace SBI accepts no responsibility for damage or injuries Follow the television manufacturer s installation instructions including any recommen...

Page 28: ...the fireplace to the center of the termination must not be less than 7 feet 6 inches SPECIAL NOTE For each 45 elbow installed in the horizontal run the length of the horizontal run MUST be reduced by...

Page 29: ...e collar of the fireplace to the face of the outer wall Venting termination shall not be recessed into wall or siding WARNING When an existing gas fireplace heater is removed or replaced the original...

Page 30: ...hen re install the flue baffle N 1 REMOVE BAFFLE TO INSTALL FLUE RESTRICTOR N 2 FLUE RESTRICTOR N 4 REMOVE BAFFLE TO INSTALL FLUE RESTRICTOR N 3 FLUE RESTRICTOR 4 3 Clearance to Combustibles NOTICE Ma...

Page 31: ...these vertical installations From 0 to a maximum of 8 ft 8 ft of vent pipe can be used between elbows C Wall straps must be used to support offset pipe every 4 This application will require that you...

Page 32: ...O 90 ELBOWS Example Vent Runs Initial Pipe Length A Vertical B Horizontal Maximum Dimensions In Inches 12 120 10 ft 222 18 ft 6 in 24 120 10 ft 222 18 ft 6 in 36 120 10 ft 222 18 ft 6 in 48 120 10 ft...

Page 33: ...nimum clearances are maintained to the vent system Vertical runs of this system which pass through ceilings require the use of ONE ceiling firestop at the hole in each ceiling through which the vent p...

Page 34: ...irestop on the ceiling side of the previously cut and framed hole If the area above the ceiling is an attic position and secure the firestop on top of the previously framed hole NOTE Remove insulation...

Page 35: ...1 feet TWO 45 ELBOWS B A Example Vent Runs Initial Pipe Length A Vertical B Horizontal Maximum Dimensions In Inches 12 66 72 24 80 132 11 ft 36 91 204 17 ft 48 103 240 20 ft Minimum rise of the firep...

Page 36: ...Firestops are required for safety whenever the vent system passes through an interior wall an exterior wall or a ceiling These firestops act as a firebreak heat shield and as a means to insure that mi...

Page 37: ...pth down to 7 inch 178 mm below grade level The 7 inch 178 mm is measured from the center of the horizontal vent pipe as it penetrates through the wall Ensure the sidewall venting clearances are obser...

Page 38: ...LBOW STRAIGHT OUT MINIMUM 4 5 2 Cutting the Hole After the fireplace has been positioned in its permanent location the hole through the exterior wall can be cut This hole must be 13 in 330mm high x 10...

Page 39: ...th Horizontal Termination Vertical 90o Elbow To Horizontal Out The Wall Propane 24 610 mm Natural 12 305 mm 12 MINIMUM 305mm VERTICAL VENT REQUIRED MAXIMUM HORIZONTAL RUN WITH MINIMUM VERTICAL RISE AN...

Page 40: ...MORE THAN 10 FEET Note that for steep roof pitches the vent height must be increased In high wind conditions nearby trees adjoining roof lines steep pitched roofs and other similar factors can result...

Page 41: ...e same height they must be positioned at least 24 inches apart to minimize draft issues between them 12 MINIMUM 4 7 1 Approuved Venting Component The following vent systems are acceptable for use with...

Page 42: ...IBLE 9 229mm NONCOMBUSTIBLE 2 51mm D MINIMUM WIDTH FOR BACK WALL OF A RECESSED LOCATION COMBUSTIBLE 38 965mm NONCOMBUSTIBLE 24 610mm E MAXIMUM DEPTH OF 48 1219mm FOR RECESSED LOCATION ATTENTION DISCLA...

Page 43: ...local codes allow copper tubing or galvanized NOTICE Since some municipalities have additional local codes it is always best to consult your local authority and installation code The use of the follo...

Page 44: ...s must be checked for leaks by the installer This should be done with a soap solution watching for bubbles on all exposed connections and if unexposed a pressure test should be made Never use an expos...

Page 45: ...the valve from a minimum of 10 8 in w c 2 68 kPa for the purpose of input adjustment to a maximum of 14 0 in w c 3 484 kPa CAUTION If one of the procedures results in pressures in excess of 1 2 psig...

Page 46: ...e National Electrical Code ANSI NFPA 70 Latest Edition 1 Attach black wire to one side of the receptacle brass screws and white wire to opposite side of receptacle silver screws The ground wire should...

Page 47: ...d to the red and black mating connector pre installed on the control module The mating connector can be located inside the fireplace near the gas valve Locate and install the 5 8 in diameter plastic s...

Page 48: ...cordance with local codes or in the absence of local codes with the current NFPA 70 National Electric Code or CSA C22 1 canadian Electrical Code Label all wires prior to disconnectlon when servicing c...

Page 49: ...other gases unless a certified kit is used WARNING Electrical Grounding Instructions This fireplace is equipped with a three prong grounding plug for your protection against shock hazard and should be...

Page 50: ...ximately 1 4 in with one hand under the lower barrier frame edge to disengage the lower flange A DETAIL A 2 Grasp the top of the barrier and pull forward to disengage it Remove the barrier by pulling...

Page 51: ...re plugged correctly Do not handle halogen bulbs with your bare hands Oils from your skin will cause the bulb to burn out prematurely 2 Install the two accent glass panels into the metal retainer brac...

Page 52: ...f during the test firing there seems to be significant flame impingement on the cross logs there are two steps that can be taken to reduce the impingement a Pivot log left or right to move away from f...

Page 53: ...kit 8 rigid and flexible ducting E Dimensions of hot air outlet frame with elbow Dimensions of hot air outlet decorative grille with elbow A B C D E 10 1 4 259mm TYP 1 25mm TYP 8 208mm TYP 18 1 2 468...

Page 54: ...r distribution kit is installed Hot air outlets must be installed in the same room as the fireplace Do not install either outlet in adjoining or upstairs rooms If you install the outlets at different...

Page 55: ...move the insulation and the other set of knockouts inside the fireplace B Cut the bottom section E of the 2 anchor plates and screw them with the 8 screws provided F on the top of the fireplace 4 for...

Page 56: ...ng screws 3 per elbow Insert the frames B into the outlets of the elbows C Support the frame behind the non combustible liner and screw it into place Screw the frame to the outlet of the elbow C using...

Page 57: ...n B Anchor plates A All screws are included Not included in the kit 8 flexible ducting Dimensions of assembled heat distribution box and adjustable decorative plate 11 O 8 3 32 55 1 4 25 15 A B 52 9 3...

Page 58: ...must be installed in the same room as the fireplace Do not install either outlet in adjoining or upstairs rooms When forced air kit is installed in conjunction with a gravity kit the forced air device...

Page 59: ...and remove the insulation and the other set of knockouts inside the fireplace B Cut the bottom section E of the 2 anchor plates and screw them with the 8 screws provided F on the top of the fireplace...

Page 60: ...ducts B to gravity box C with self drilling screws G 3 for each telescopic section Rest the housing on the non combustible material and secure with 4 screws in the housing Fix the air circulation pla...

Page 61: ...inishing Trim6 Black AC04333 Driftwood And River Rocks Kit7 AC04334 Birch and river rock kit7 AC04343 Ledgestone ceramic panels5 AC04344 Waved ceramic panels5 AC04345 River rocks7 AC04346 Grooved glas...

Page 62: ...com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to time a...

Reviews: