background image

 

 

 

Output 

Rated Power: 

144 Watts 

Voltage: 

24 Volts 

Current: 

6 Amps (3 - 2 Amp outputs) 

Fusing: 

3 - 2 Amps, auto-reset polyswitch fuses 

Ripple and Noise:  

1% P-P maximum 

 

Environmental 

Operating Temperature: 

0 to +40

o

Storage Temperature: 

-40

o

 to +85

Cooling: 

Free Air Convection 

Humidity: 

10 to 90% (non-condensing) 

Shock: 

10G 

 

Precautionary Notes:

 

 

FCC 

This device complies with part 15 of the FCC Rules.  
Operation is subject to the following two conditions: 

• 

This device may not cause harmful interference. 

• 

This device must accept any interference 
received, including interference that may cause 
undesired operation. 

NOTE:  This equipment has been tested and found 
to comply with the limits for a Class B digital 
device, pursuant to part 15 of the FCC Rules.  
These limits are designed to provide reasonable 
protection against harmful interference in a 
residential installation.   This equipment 
generates, uses and can radiate radio frequency 
energy and if not installed and used in accordance 
with the instructions, may cause harmful 
interference to radio communications.  However, 
there is no guarantee that interference will not 
occur in a particular installation.  If this 
equipment does cause harmful interference to 
radio or television reception, which can be 
determined by turning the equipment off and on, 
the user is encouraged to try to correct the 
interference by one or more of the following 
measures:  

• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the 
equipment and receiver. 

• 

Connect the equipment into an outlet on a 
circuit different from that to which the 
receiver is connected. 

• 

Consult the dealer or an experienced 
radio/TV technician for help. 

 

INSTALLATION 
Mounting 

The VP-6124 and VP-6124-E are designed for 

wall 

mounting only

.  The unit should be mounted within 

seven feet of an AC receptacle. 
 

• 

Screw mounting plate to wall and position power 
supply on mounting plate via the mounting slots. 

• 

See page 4 for mounting instructions.  

 
Connections

 

• 

Connections to Valcom page control units are 
shown in Figure 1. 

• 

When using the VP-6124 or VP-6124-E with 
Valcom page equipment, a strap may be added 
from the local ground terminal to either of the  
"+" outputs. 

• 

When installing Valcom one-way amplified 
horns, connect the white and black wires of the 
horn to the power supply "-" and "+" terminals 
respectively. 

• 

When installing Valcom one-way speakers, 
connect the "-24VDC" and "GND" terminals of 
the speaker to the "-" and "+" terminals 
respectively. 

• 

Plug power supply into wall outlet. 

• 

Power supply activates after a 3 seconds delay. 

• 

Use CAT-5 wire. 

NOTE:  Each 24VDC screw terminal is fused by a 
2 Amp polyswitch automatic type fuse.  Therefore, 
when connecting equipment to this power supply, 
the load should be distributed between the (3) 2 
Amp output terminals and each load should not 
exceed 2 Amps. 

CAUTION:  To reduce the risk of electric shock,

Do not remove cover.

No user serviceable parts inside.

Refer servicing to qualified service personnel.

This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.

This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

 

Reviews: