background image

 

  Unplug the power supply before making any 

connections to the control unit. 

  Do not locate the control unit closer than 18 

inches or further than five feet from power 
supply. 

  Do not use a lamp tester to check signals; 

use a voltmeter.  A lamp tester when first 
applied is a short circuit to electronic circuits. 

  Do not apply power to the control unit until all 

connections have been double checked. 

Mounting

 

Mount the unit in a vacant space in an equipment 
cabinet, rack or key system cabinet, allowing 
enough room at the rear of the unit to plug in an 
amphenol connector.  Mount a 66B type 
punchdown block near the unit and label it per 
Figure 1. 

 

Cabling

 

A 25 pair cable with a female connector should be 
ran from the unit to the connection block.  The 
cable should be terminated on the connection 
block in standard color code order.  Verify that the 
connections are correct prior to plugging the other 
end of the cable into the V-1109RTVA Page Unit. 

 

Connections to PABX System

 

The V-1109RTVA may be accessed by 
connecting the W/BL and BL/W to the Tip and 
Ring respectively of a Loop Start Trunk Circuit.  
Refer to Figure 2 for connections

 

Connections to Electronic Key 
Systems

 

The V-1109RTVA may be accessed by a C.O. 
line position of an Electronic Key System by 
connecting the W/BL, BL/W of the V-1109RTVA 
to a spare line position of the Electronic Key.  This 
line position must be equipped with a trunk card.  
Refer to Figure 2 for connections. 

 

Connections to 1A2 Key System

 

The V-1109RTVA may be connected to a spare 
button of a 1A2 Key Telephone by making the 
following connections: 

 (A 400 type line card is 

not needed in this application).

 

 

  W/BL, BL/W of V-1109RTVA to spare button 

Tip and Ring  

  O/W to Lamp Lead of spare button for lamp 

connections   

  W/GR to Lamp Ground lead of spare button 

 
 

NOTE:  When the V-1109RTVA is connected to 
a 1A2 Key System, connect W/O to Lamp 

Battery or Ground.  See Figure 3. 

 

NOTE:  For "Meet Me Page" on 1A2, connect 
A-Leads from spare button using 10K Ohm 
resistors in series with each A-Lead.  The 
other side of resistors are connected to the 
BK/G (inhibit) of V-1109RTHF.  Refer to Figure 
3 for connections. 

Power Connections

 

  The V-1109RTVA is designed to use -24VDC 

battery. 

  Connect the V/BR lead to Talk Ground. 

  Connect the BR/V lead to Talk Battery 

(-24VDC filtered). 

  Connect the V/S lead to Signal Ground. 

  Connect the S/V lead to Signal Battery 

(-24VDC unfiltered). 

 

Speaker Connections

 

The outputs for paging zones start at the BK/BR 
pair (zone 1) through the V/O pair (zone 9).  Refer 
to Figure 3 for typical speaker connections using 
Valcom one-way amplified speaker assemblies

 

Page and Music Level Set-up

 

The V-1109RTVA has volume controls for the 
following functions: 
 

  Master Page Control - located on back of unit 

below amphenol connector 

  All Call Master Control - located on front of 

unit 

  Background music input control Zones 1-5 

  Background music input control Zones 6-9 

 

Control Set-Up:

 

1.  Master Page Control: 
    This control sets the level of the page out of      
  the page control unit.  The control should be      
rotated clockwise to about 50% of its travel.       
After setting control, the individual speaker        
volume controls should be set to the desired      
level. 
2.  All Call Level: 
    The All call level should be set to produce the 
    same audio level as the phone to speaker         
 page control.  THIS ADJUSTMENT                    
SHOULD BE MADE AFTER INDIVIDUAL          
SPEAKER LEVELS HAVE BEEN SET. 
3.  Background Music Levels: 
     There are two volume controls provided for 
     background music adjustments:  Zones 1-5      
  and Zones 6-9. It is important that the two 
background music controls be used to set the 
music levels in the system.  Adjust these controls 
after all other system volume levels have been 

Summary of Contents for V-1109RTVA

Page 1: ...ment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television r...

Page 2: ...99cm W x 5 33cm D 2 7 lbs 1 23 kg Power Requirements The Valcom V 1109RTVA requires 24VDC talk battery and 24VDC signal battery The current consumption and voltage range is shown in Table 1 TABLE 1 T...

Page 3: ...n for lamp connections W GR to Lamp Ground lead of spare button NOTE When the V 1109RTVA is connected to a 1A2 Key System connect W O to Lamp Battery or Ground See Figure 3 NOTE For Meet Me Page on 1A...

Page 4: ...itry to provide a ringback tone and a one way connection for the zone selected TECHNICAL ASSISTANCE When trouble is reported verify that power is being supplied to the unit and there are no broken con...

Page 5: ...riod provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the original shipment 3 the product has not been a...

Page 6: ...6...

Page 7: ...N D R IN G G Y R E T A B A G S P K9 G V B R V V BR V G O Y V O Y S B L S V BL S Y Y BR B R Y S P K1 R E T S BK Y O Y G O Y B L Y Y BL B R BK B K BR B K S G BK B K G P O S ITIO N V A LC O M O N E W AY...

Page 8: ...G N D 24 TIP R IN G BL Y G Y BR Y Y BR Y S Y O Y G O Y BK S S BK Y BL G BK BK BR BR BK Figure 3 1A2 Key System C onnections Speaker C onnections and Pow er C onnections VALC O M O N E W AY TELEPH O N...

Page 9: ...9...

Reviews: