7.3. ELECTRICAL FAULTS:
Circuit
Breaker
that
supplies energy to the unit
trips
Check electrical leakage in
unit
resistance
and
peripherals
Check that the breaker is
the right one for the unit
power requirement
The machine does not
come on
Check the connection
of the power supply to the
machine
Check the power fuses of the
electronic card
The unit turns on, but is not
enabled
Check
that
the
unit
is
programmed with the correct
parameters
Check the over temperature
thermostat
The Tank overheats
Check the Tank RTD
Check if the zone triac is
short circuited
Check
for
the
correct
Control Board functioning
Check the programmed tank
temperature