Table 1. General parameter codes (standard default values in brackets):
Nombre
Descripción
P0
Enter password (000)
To enter the access code in order to change the level access.
[000,255]
P1
Level access (0).
Shape the level access to the equipment. [0,1,2]
P2
Measurement unit (0)
Selects the measurement unit. 0 = ºC and 1 = ºF.
P3
Clearance delay (15)
Delay in minutes for switching on the pump and giving clearance
after pre-heating. Values between 0 and 60 minutes.
P4
Maximum temperature
(240 ºC / 464 ºF).
This temperature must be above preset operating temperature.
[80, 240ºC; 176, 464 ºF].
P5
Tank alarm deviation
(5 ºC /9 ºF).
Any sensor that reaches a temperature higher or lower than
operating tempe/- deviation, will switch on the temperature
warning lamp and the relevant external alarm.[1, 30ºC; 2, 54ºF].
P6
Hose alarm deviation
(5 ºC /9 ºF).
Any sensor that reaches a temperature higher or lower than
operating temperature +/- deviation will turn on the temperature
warning lamp and the relevant external alarm. [1, 30ºC; 2, 54ºF].
P7
Gun alarm deviation
(5 ºC /9 ºF).
Any sensor that reaches a temperature higher or lower than
operating temperature +/- deviation will turn on the temperature
warning lamp and the relevant external alarm. [1, 30ºC; 2, 54ºF].
P8
Time after last signal (0) to
go into ENERGY SAVING
If the selected time (between 1 and 225 minutes) is exceeded with no
shot pulses, the equipment will go into ENERGY SAVING mode. A 0
value switches off this function.
(I/O CARD REQUIRED)
P9
Time counter
Displays the time (hours) that the equipment has been operating
P10
Time
between
filter
change (2000)
In normal conditions, the filter must be changed every 2000 working
hours. Depending on the adhesive type, this parameter can be set
within this range: [0, 2000].
P11
Enable/Disable
hose-gun
channel 1 (0)
It disables the channel 1, P11=1. [0,1]
P12
Enable/Disable
hose-gun
channel 2 (0)
It disables the channel 2 P12=1. [0,1]
P13
Enable/Disable
hose-gun
channel 3 (0)
It disables the channel 3 P13=1. [0,1]
P14
Enable/Disable
hose-gun
channel 4 (0)
It disables the channel 4 P14=1. [0,1]
P15
Enable/Disable
hose-gun
channel 5 (0)
It disables the channel 5 P15=1. [0,1]
(ONLY IN 6 EXITS
EQUIPMENTS)
P16
Enable/Disable
hose-gun
channel 6 (0)
It disables the channel 6 P16=1. [0,1]
(ONLY IN 6 EXITS
EQUIPMENTS)
P17 Node number (0)
It identify the node number for communications. (4exits and 6exits)
Summary of Contents for D4-L
Page 2: ......
Page 4: ......
Page 6: ......
Page 95: ...0 1 2 1 1 3 4 53 6 0 53...
Page 97: ...0 1 2 3 4 5 4 0 2 4 6 7 1 1 8 3 7 7 2 02 2 90 1 8 7 2 7...
Page 98: ...0 1 2 103 1 4 5 6 7 3 5 0 8 4 4 9 6 10 7 8 8 8 0 8 8 8 8 8...
Page 99: ...0 1 2 3 4 5 6 5 1 3 5 7 7 2 2 8 4 9 9 9 7 9 7 5 3...
Page 101: ...0 1 2 3 4 5 6 7 87 9 6 7 878 3 9 94...
Page 102: ...0 0 1 2 3 4 5 6 2 3 3 7 4 45...