Example
>setalr active 1
ACTIVE = 1
DIR = 60
SPD = 60
CALM = 1440
DIRLIMIT= 3
SPDLIMIT= 0.0
SDPVOLTLIMIT = 0.2
DIRVOLTLIMIT = 0.2
>
More information
‣
Wiring WAA252 and WAV252 with WAC155 (page 23)
4.3.12 SERVICE TIMEOUT
The
SERVICE TIMEOUT
command configures the timeout of the auto-close function of the
service connection. If there is no data input within the configured time interval, the device
closes the service connection and returns to normal operational state.
Zero value disables the auto-close function, which means that the service connection never
closes unless intentionally closed using the
CLOSE
command.
SERVICE TIMEOUT <value><cr>
value
Value of the service timeout, range 0 ... 30 min. Default value: 5 min.
Example
>service timeout 30
TIMEOUT=30
>
4.3.13 GETSET
The
GETSET
command returns the current configuration of the unit.
GETSET <cr>
The following example uses factory default values.
Chapter 4 – Operation