![Vaisala WAC155 User Manual Download Page 40](http://html1.mh-extra.com/html/vaisala/wac155/wac155_user-manual_3468399040.webp)
Example
>setmes 1 type mwvquery
0 TYPE=NONE INTERVAL=0.00
1 TYPE=MWVQUERY INTERVAL=0.00
2 TYPE=NONE INTERVAL=0.00
3 TYPE=NONE INTERVAL=0.00
>setmes 0 type mwv interval 2
0 TYPE=MWV INTERVAL=2.00
1 TYPE=MWVQUERY INTERVAL=0.00
2 TYPE=NONE INTERVAL=0.00
3 TYPE=NONE INTERVAL=0.00
>setmes 0 interval 8
0 TYPE=MWV INTERVAL=8.00
1 TYPE=MWVQUERY INTERVAL=0.00
2 TYPE=NONE INTERVAL=0.00
3 TYPE=NONE INTERVAL=0.00
4.3.7 SETMEA
The
SETMEA
command configures the essential measurement parameters.
SETMEA [gaincorr] [offset] [powersave] [allowedspdchange] [maxinvalidspdcount]
[thies] [calibmin] [calibmax] <value><cr>
gaincorr
Anemometer transfer function gain parameter. Range: 0.0 … 10.0
(default: 0.101).
offset
Anemometer transfer function offset parameter. Range: -10.0 … 10.0
(default: 0.348).
powersave
Defines whether sensor power is pulsed or provided continuously.
Pulsing saves power as the sensors are only powered when read.
0 = Continuous power
1 = Pulsed power (default); not used with WA25
allowedspdchange
Maximum allowed difference in m/s between two adjacent samples
in the sensor data. Range: 0.1 ... 25.0 (default: 10.0).
maxinvalidspdcount
Maximum number of adjacent discarded samples in sensor data.
Value 0 deactivates the check. Range: 0 ... 15 (default: 2).
thies
Defines the sensor type:
0 = Vaisala WA15 or WA25 series (default)
1 = Thies first class anemometer and analog vane (default values for
gaincorr
and
offset
are automatically changed accordingly)
calibmin
4 mA calibration value for analog vane (default: 540)
WAC155 User Guide
M210822EN-E
38
Summary of Contents for WAC155
Page 1: ...M210822EN E User Guide Vaisala Serial Wind Transmitter WAC155...
Page 56: ......
Page 57: ......
Page 58: ...www vaisala com...