4.6 Connecting cables and grounding
In standard delivery you need to connect only the serial or Ethernet cable and the power
cable.
The Ethernet cable must be a pair cable with shield grounding (Ethernet FTP CAT5).
Make sure that you prepare or connect only de-energized wires.
WARNING!
Table 2 Minimum and maximum cross-sections for connection cables
Cable type
Cross-section
Data cable
Solid
0.14 … 1.5 mm
2
Stranded
0.14 … 1.5 mm
2
Stranded with ferrule without plastic sleeve
0.25 … 1.5 mm
2
Stranded with ferrule with plastic sleeve
0.25 … 0.5 mm
2
Power cable
Solid
0.2 … 2.5 mm
2
Stranded
0.2 … 2.5 mm
2
Stranded with ferrule without plastic sleeve
0.25 … 2.5 mm
2
Stranded with ferrule with plastic sleeve
0.25 … 2.5 mm
2
In standard delivery, connectors marked as
NOT IN USE
are not for customer
use.
CAUTION!
Polarization features of the connectors prevent incorrect mating.
If you are using the connector plate, the following figure does not apply.
WID511 User Guide
M211109EN-L
20