Installation Manual Start-up Current Limiter VWZ 30/2 0020057445_00
6
4.2
Connecting the start-up current limiter
(for VWS/VWW 61/2, 81/2, 101/2, 141/2,
171/2 and VWS 64/2, 84/2, 104/2)
• Fit the start-up current limiter PCB underneath the
electrical installation panel (
1
) by clipping the PCB into
the retainers provided.
h
Note
Take care that the current limiter PCB is
correctly latched in the retainers!
L3 L2
L3
L1
L2 L1
L1 L2
L3'
L3
N N
L3 N PE
L1 L2
L3'
L3
N N PE
L1 L2 L3 N
L1 L2 L3
L1
N PE
L3
L2
L3 L2 L1 L3 L2 L1
1
ASB
N L 2 1
8
A8-30-01
L1 L2 L3
L1 L2 L3
2
3
4
1
Fig. 4.2 Connecting the start-up current limiter PCB
to the VWS/VWW 61/2, 81/2, 101/2, 141/2, 171/2 and
VWS 64/2, 84/2, 104/2
Key
1 Fit the PCB underneath the electrical installation panel
2 Remove the jumpers
3 Connect the control cable
4 Connect the connecting cables
• Remove the three factory-fitted jumpers (
2
, dashed
lines).
• Connect the accompanying control cable from the
current limiter to the main PCB (
3
).
• Connect the input and output cables from the current
limiter to the connection terminals, paying attention
to the correct phase and colour (
2
and
4
).
a
Caution!
Risk of overheating!
The control and connecting cables must not be
run over either the main PCB or the current
limiter PCB.
Run the cables to the current limiter along the
side of the PCBs.
4 Installation
Summary of Contents for VWZ 30/2 SV
Page 1: ...VWZ 30 2 SV ES GB HR RU SI UA...
Page 2: ......
Page 11: ...For the installer Installation manual Start up current limiter for heat pumps VWZ 30 2 SV GB...
Page 20: ......
Page 21: ...Za obrtnika Upute za monta u Ograni iva polazne struje za toplotnu crpku VWZ 30 2 SV HR...
Page 29: ...VWZ 30 2 SV RU...
Page 45: ...VWZ 30 2 SV UA...
Page 53: ......
Page 54: ......
Page 55: ......