Installation instructions 0020140122_04
19
8
Decommissioning
>
Switch off the product.
>
Isolate the product from the power mains.
>
De-install the product.
>
Recycle or dispose the product and its components (see
chapter 9).
9
Recycling and disposal
This product is an electrical or electronic unit within the con-
text of EU Directive 2012/19/EU. The unit was developed
and manufactured using high-quality materials and compo-
nents. These can be recycled and reused.
Find out about the regulations that apply in your country
regarding the separate collection of waste electrical or elec-
tronic equipment. Correctly disposing of old units protects
the environment and people against potential negative
effects.
>
Dispose of the packaging correctly.
>
Observe all relevant regulations.
Disposing of the product
If the product is labelled with this symbol:
>
In this case, do not dispose of the product with the
household waste.
>
Instead, hand in the product to a collection centre for
waste electrical or electronic equipment.
Disposing of batteries
If the product contains batteries that are labelled
with this symbol:
>
In this case, dispose of the batteries at a collection point
for batteries.
–
Prerequisite:
The batteries can be removed from the
product without causing any destruction. Otherwise,
the batteries are disposed of together with the prod-
uct.
>
In accordance with the legal regulations, the end user is
obligated to return used batteries.
Deleting personal data
Personal data may be misused by unauthorised third par-
ties.
If the product contains personal data:
>
Ensure that there is no personal data on or in the prod-
uct (e.g. online login details or similar) before you dis-
pose of the product.
10 Customer service
For contact details for our customer service department,
you can write to the address that is provided on the back
page, or you can visit www.vaillant.co.uk.
11 Technical data
Description
Unit
VR 66/2
Power-supply voltage
V, Hz
230, 50/60
Power consumption
W
20
Contact load of output relays
(max.)
A
2
Delay fuse
A
T 4 A/250 V
Contact voltage for DHW cylinder
thermostat
V
230
Temperature sensor (NTC) operat-
ing voltage
V
5
Thermistor NTC at 25°C
kOhm 2.7
eBUS connection cable gauges
mm
2
2 x 0.75
Maximum length of eBUS cable
m
300
Power cable gauge
mm
2
3 x 1.5
Maximum length of power cable
m
10
Dimensions :
– Height
mm
185
– Length
mm
281.3
– Depth
mm
49.5
Electrical protection
IP20
Electrical classification
I