Detecting and rectifying faults
Fault
Possible cause
Remedy
No flow rate at the water
tap
1.
The water supply valve is closed.
2.
The main filter is blocked.
3.
The pressure reducer is not installed correctly.
1.
Check and open the water supply valve.
2.
Close the water supply valve, clean the filter
and the water pressure reducer.
3.
Check whether the pressure reducer has been
installed correctly.
Low flow rate and pres-
sure at a water tap
1.
The filter in the cold water supply is clogged.
1.
Close the cold water supply, clean the filter for
the water pressure reducer.
Water from the water tap
is cold
1.
The cylinder was not started up.
2.
The water supply valve is not fully open.
3.
The heat generator is not operating.
4.
The thermal cut-out was triggered.
5.
The 2-port motorised valve is defective.
6.
The immersion heater is defective.
1.
Open all of the relevant valves.
2.
Check the thermostat or the room thermostat
and, if required, set this.
3.
Check the heat generator to see if a fault code
is present.
4.
Check and initialise the cylinder.
5.
Check the connections for the 2-port motorised
valve.
Hot water temperature at
the water tap too high
1.
The thermostat is set too high.
2.
The thermostatic valve is not present or is
defective.
1.
Check the temperature. It must be between 60
and 65 °C.
2.
Install a mixer valve.
3.
Check the cabling. Repair the cable.
4.
Reduce the temperature of the thermostat to
60 °C.
5.
Replace the thermostatic valve.
Irregular domestic hot
water output at the water
tap
1.
The expansion vessel is defective.
2.
The thermal cut-out has been triggered
(thermal control).
1.
Compare the temperature between the con-
trols. The maximum temperature has priority.
2.
Set the expansion vessel.
3.
Interrupt the power supply to the product and
the heat generator. Check the thermal cut-outs
and replace these in the event of a defect.
VIH .. .../3 MR only
The control panel does
not display any func-
tions.
1.
The power supply is interrupted.
1.
Reconnect the power supply.
2.
Check the plug connection.
VIH .. .../3 MR only
F.01/F.02
1.
Interruption in the cable for the top (
F.01
) or
bottom (
F.02
) cylinder temperature sensor
2.
Top (
F.01
) or bottom (
F.02
) cylinder temperat-
ure sensor is defective.
1.
Check the cable for the cylinder temperature
sensor.
2.
Replace the cable harness.
VIH .. .../3 MR only
F.03
1.
The external current anode is defective.
2.
The cylinder is corroded.
1.
Check the electrical connections.
2.
Replace the external current anode.
3.
Replace the cylinder.
B
Inspection and maintenance work
–
Overview
The table below lists the manufacturer requirements with respect to minimum inspection and maintenance intervals. If na-
tional regulations and directives require shorter inspection and maintenance intervals, you should observe these instead of
the intervals listed.
#
Maintenance work
Interval
1
Check the connections for tightness (visual inspection).
Annually
2
Check the temperature and pressure expansion relief valve (by actuating
it).
Annually
3
Check the pressure in the expansion vessel (annual manometer).
Annually
4
Check the tightness of the flange in the cleaning eye (visual inspection)
Annually
5
Check the state of wear of the magnesium protection anode
Annually
6
Clean the cylinder
Annually
7
Check the contacts of the external current anode for corrosion
Annually
Summary of Contents for VIH R Series
Page 61: ...1 0020241666_01 59 1 1 1 1 2 85 C IP 1 3 1 3 1 Vaillant...
Page 62: ...1 60 0020241666_01 1 3 2 3 mm 3 1 3 3 1 3 4 1 3 5 1 3 6 1 4...
Page 65: ...6 0020241666_01 63 6 6 1 64 6 2 7 1 2 3 4 5 8 9...
Page 177: ...1 0020241666_01 175 1 1 1 1 2 85 C IP 1 3 1 3 1 Vaillant 1 3 2 3 mm 3...
Page 178: ...1 176 0020241666_01 1 3 3 1 3 4 1 3 5 1 3 6 1 4...
Page 181: ...7 0020241666_01 179 7 1 2 3 4 5 8 9...
Page 218: ...1 216 0020241666_01 1 1 1 1 2 85 C IP 1 3 1 3 1 Vaillant...
Page 219: ...1 0020241666_01 217 1 3 2 3 mm 3 1 3 3 1 3 4 1 3 5 1 3 6 1 4...
Page 222: ...6 220 0020241666_01 6 6 1 221 6 2 7 1 2 3 4 5 8 9...
Page 290: ...1 288 0020241666_01 1 1 1 1 2 85 C IP 1 3 1 3 1 Vaillant...
Page 291: ...1 0020241666_01 289 1 3 2 3 3 1 3 3 1 3 4 1 3 5 1 3 6 1 4...
Page 294: ...6 292 0020241666_01 6 6 1 293 6 2 7 1 2 3 4 5 8 9...
Page 390: ...1 388 0020241666_01 1 1 1 1 2 85 C IP 1 3 1 3 1 Vaillant...
Page 391: ...1 0020241666_01 389 1 3 2 3 3 1 3 3 1 3 4 1 3 5 1 3 6 1 4...
Page 394: ...6 392 0020241666_01 6 6 1 393 6 2 7 1 2 3 4 5 8 9...
Page 405: ...1 0020241666_01 403 1 1 1 1 2 85 C IP 1 3 1 3 1 Vaillant 1 3 2 3 mm 3 1 3 3 1 3 4 1 3 5...
Page 406: ...1 404 0020241666_01 1 3 6 1 4...
Page 409: ...8 0020241666_01 407 8 9...
Page 427: ......