Operation 4

Instructions for use turboMAX plus, thermoCOMPACT

Heating operation
Setting the maximum radiator temperature control 

• Turn the main switch (1) to the „l“ position.
• Set the maximum radiator temperature control to the

desired setting using the control knob (2). We recom-
mend the following settings:
- Left setting during spring and autumn,
- Middle setting during mild winter,
- Right setting during cold winter.

Fig. B.8: Setting the flow temperature

Setting the external controls 

• Set the room thermostat (3) and/or the thermostatic

radiator valves (4) according to the instructions 
supplied with the control(s).

Hint! 
Vaillant offer room thermostat/time control
accessories which give accurate and economic
room temperature control as well as improved
comfort. Ask your installer!

Fig. B.9: Setting the external controller 

The boiler will now operate automatically to provide central
heating for the conditions selected on the external con-
trols (turboMAX plus will also provide domestic hot
water on demand). Whilst the boiler is operating, the
boiler display (fig. B.2) indicates the temperature of the
water within the boiler circuit. After the boiler stops
operating the pump and fan will continue to operate for
a short period to fully disperse the heat from the boiler.

The boiler incorporates an anti-cycling economi-
ser control to prevent energy wasteful ON and
OFF operation of the boiler for short periods
when in the central heating mode. When turning
the room thermostat to a higher setting there
may therefore be a short delay before the boiler
operates.

Resetting the appliance

Fig. B.10: Reset 

Fig. B.11: Reset 

C

o

0

I

C

o

VRC-VC

2

STOP

max. 3 x

C

o

0

I

C

o

VRC-VC

1

3

4

VRC-VC

C

o

0

I

C

o

1

2

C

o

C

o

C

o

833690_24GB_012006.qxd  13.12.2005 12:27 Uhr  Seite 7

Summary of Contents for thermoCOMPACT

Page 1: ...GB Instructions for use turboMAX plus thermoCOMPACT...

Page 2: ...s This symbol is used to indicate a required step Liability We can accept no liability whatsoever for damage or injury resulting from failure to obser ve these instructions Specified use Vaillant turb...

Page 3: ...r service agent or Vaillant Ltd Attention The device may only be used for initial operation for testing for continuous operation with the chamber cover closed and with the flue system fully mounted an...

Page 4: ...rols press the upper middle of the lower front panel and drop it down The following can be seen 1 Maximum radiator temperature control 2 The and buttons for the display panel 3 Main ON OFF control 4 B...

Page 5: ...u re gauge 1 The needle on the pressure gauge should be within the green band between 1 and 1 5 bar If the needle displays a value below 0 8 bar when the appliance is cold follow the instructions left...

Page 6: ...ndicator light will now illuminate Reset the hot water temperature control knob to the desired setting The boiler will now provide instantaneous delivery of hot water directly when a hot water tap is...

Page 7: ...rt Ask your installer Fig B 9 Setting the external controller The boiler will now operate automatically to provide central heating for the conditions selected on the external con trols turboMAX plus w...

Page 8: ...ich prevents the boiler from operating the display will also show other fault codes If a fault code is displayed please contact your installer or Vaillant Service Solutions Note If contacting Vaillant...

Page 9: ...Vaillant Service Solutions 0870 6060777 Frost protection Your boiler is equipped with a frost protection function If the heating water temperature drops below 5 C when the main switch is ON then the...

Page 10: ...lt your installer or Vaillant Service Solutions 0870 6060 777 Status display For maintenance and service work performed by your installer or service agent The status displays are activated by pressing...

Page 11: ...0...

Page 12: ...83 36 90 _24 GB_R1 01 2006 Subject to alteration...

Reviews: