Product description 2
0020298974_00
sensoHOME
Operating and installation instructions
9
MENU
→
CONTROL
→
Mode:
Weekly planner
: Up to 12 time periods and desired temperatures can
be set per day
The competent person sets how the heating installation behaves out-
side of the time period in the
Set-back mode:
function.
In
Set-back mode:
means:
–
Eco
: The heating is switched off outside of the time periods. Frost
protection is activated.
–
Normal
: The set-back temperature applies outside of the time peri-
ods.
Desired temperature: °C
: Applies within the time periods
→
Off
Heating is switched off, domestic hot water continues to be available,
frost protection is activated
→
Absence
→
All
: Applies only to any zones within the specified time period
→
Zone
: Applies for the selected zone in the specified time period
Heating and domestic hot water mode is switched off; frost protection
is activated
→
Domestic hot water
→
Mode:
→
Manual
→
DHW temperature
Uninterrupted retention of the domestic hot water temperature
→
Time-contr.
→
Domestic hot water weekly planner
→
DHW temperature: °C
→
Circulation weekly planner
Domestic hot water weekly planner
: Up to three time periods can be
set per day
DHW temperature: °C
: Applies within the time periods
Domestic hot water mode is switched off outside of the time periods
Circulation weekly planner
: Up to three time periods can be set per
day
The circulation pump pumps hot water to the draw-off points within the
time periods
Outside of the time periods, the circulation pump is switched off
→
Off
Domestic hot water mode is switched off
→
DHW boost
Heating up the water in the cylinder once
→
Ventilation boost
Heating mode is switched off for 30 minutes.
→
Time programme
assistant
Programming of the desired temperature for Monday
–
Friday and Sat-
urday
–
Sunday; the programming applies for the time-controlled
Heat-
ing
,
Domestic hot water
and
Circulation
functions.
Overwrites the weekly planner for the
Heating
,
Domestic hot water
and
Circulation
functions.
→
Sytem off
Installation is switched off. Frost protection remains active