Product description 2
0020288151_00
sensoCOMFORT
Operating and installation instructions
65
MENU
→
CONTROL
→
Air quality limit: ppm
The ventilation unit keeps the CO
2
content in the room air below the set value.
→
Ventilation boost
Heating mode is switched off for 30 minutes and, if available, the ventilation unit runs at the highest
ventilation level.
→
Humidity prevention
→
Max. room air humidity: %rel
: If the value is exceeded, the dehumidifier switches on. If the value
is not reached, the dehumidifier switches off.
→
Time programme assistant
Programming of the desired temperature for Monday
–
Friday and Saturday
–
Sunday; the program-
ming applies for the time-controlled
Heating Cooling
,
Domestic hot water
,
Circulation
and
Ventil-
ation
functions
Overwrites the weekly planner for the
Heating
,
Cooling
,
Domestic hot water
,
Circulation
and
Ventilation
functions
→
Green iQ:
Switching on the most energy-efficient heating mode, if your installation supports this.
→
Sytem off
Installation is switched off. Frost protection and, if available, ventilation remain activated at the lowest
level.
2.12.2 INFORMATION menu item
MENU
→
INFORMATION
→
Current temperatures
→
Zone
→
DHW temperature
→
DHW circuit 1
→
Water pressure: bar
→
Current room air humidity
→
Energy data
→
Solar yield
→
Environmental yield
→
Power consumption
→
Heating
→
Domestic hot water
→
Cooling
→
Installation
→
Fuel consumption
→
Heating
→
Domestic hot water
→
Installation
→
Heat recovery
Display of energy consumption and energy yield
In the display and in the app that can also be used, the control displays values for the energy consumption and/or the energy yield.
The control displays an estimation of the values for the installation. Among other things, the values are influenced by the following:
–
The installation/design of the heating installation
–
User behaviour
–
Seasonal environmental conditions
–
Tolerances and components
External components, such as external heating pumps or valves, and other consumers and appliances in the household are still not
taken into consideration.
The deviations between the energy consumption or energy yield that is displayed and the actual energy consumption or energy yield
may be significant.
The specifications for the energy consumption or energy yield are not suitable to be used to create or compare energy billing.
The following can be read:
Current month
,
Last month
,
Current year
,
Last year
,
Total
→
Burner status:
→
Control elements
Explanation of the control elements
→
Menu introduction
Explanation of the menu structure
→
Competent person contact info
→
Serial number