Information about the product 7
0020288151_00
sensoCOMFORT
Operating and installation instructions
107
7.6
Guarantee and customer service
7.6.1
Guarantee
You can find information about the manufacturer's guarantee
in the Country specifics.
7.6.2
Customer service
The contact details for our customer service are provided on
the back page or on our website.
7.7
Recycling and disposal
▶
The competent person who installed your product is re-
sponsible for the disposal of the packaging.
If the product is labelled with this mark:
▶
In this case, do not dispose of the product with the
household waste.
▶
Instead, hand in the product to a collection centre for
waste electrical or electronic equipment.
----- Packaging -----------------
▶
Dispose of the packaging correctly.
▶
Observe all relevant regulations.
7.8
Product data in accordance with EU
Ordinance no. 811/2013, 812/2013
On units with integrated weather-compensated controls, in-
cluding a room thermostat function that can be activated, the
seasonal room-heating efficiency always includes the cor-
rection factor for control technology class VI. The seasonal
room-heating efficiency may deviate if this function is deac-
tivated.
Temperature control class
VI
Contribution to the seasonal room-heat-
ing energy efficiency ɳs
4.0 %
7.9
Technical data
7.9.1
System control
Battery type
LR06
Rated surge voltage
330 V
Frequency band
868.0
… 868.6 MHz
Max. transmission power
< 25 mW
Range outdoors
≤
100 m
Range indoors
≤
25 m
Pollution degree
2
IP rating
IP 20
Protection class
III
Temperature for the ball pressure test
75
℃
Maximum permitted environmental tem-
perature
0 … 45
℃
Current room air hum.
35 … 95 %
Mode of operation
Type 1
Height
109 mm
Width
175 mm
Depth
27 mm
7.9.2
Radio receiver unit
Rated voltage
9 to 24 V
Rated current
< 50 mA
Rated surge voltage
330 V
Frequency band
868.0
… 868.6 MHz
Max. transmission power
< 25 mW
Range outdoors
≤
100 m
Range indoors
≤
25 m
Pollution degree
2
IP rating
IP 21
Protection class
III
Temperature for the ball pressure test
75
℃
Maximum permitted environmental tem-
perature
0 … 60
℃
Rel. room humidity
35 … 90 %
Supply line cross-section
0.75 … 1.5 mm
²
Height
115.0 mm
Width
142.5 mm
Depth
26.0 mm
7.9.3
Outdoor temperature sensor
Power supply
Solar cell with
energy store
Reserve power supply (with full energy
store)
≈
30 days
Rated surge voltage
330 V
Frequency band
868.0
… 868.6 MHz
Max. transmission power
< 25 mW
Range outdoors
≤
100 m
Range indoors
≤
25 m
Pollution degree
2
Level of protection
IP 44
Protection class
III
Temperature for the ball pressure test
75
℃
Permissible operating temperature
−
40 … 60
℃
Height
110 mm
Width
76 mm
Depth
41 mm