Start-up 6
0020236694_04 recoVAIR Installation instructions
41
5.5.5 Sliding the regenerator into the
pipe
1
3
2
1. Check that the tension cable is posi-
tioned securely on the regenerator
(1)
before sliding it in.
2. Slide the regenerator with the filters
(2)
and
(3)
that have already been in-
stalled into the pipe until it approxim-
ately reaches the centre of the wall.
Conditions
: Installation dimensions: < 300 mm
(< 11.81 in)
–
Leave out the inner filter
(3)
.
–
The regenerator and tension cable
must not touch the fan's impeller.
5.5.6 Installing the fan unit
A
B
1. Install the fan unit with the wind guard
and front panel (that have already been
fitted) on the wall-mounting frame.
2. Ensure that the contact for the plug
connection has been correctly estab-
lished on the wall-mounting frame.
6 Start-up
6.1 Switching on the product
Applicability:
VAR 60/1 D
▶
Use the VAZ RC remote control to
initialise all of the ventilation units in
the system one after the other.
–
See the operating instructions for
the remote control.
Note
When using an optional VAZ
CPC control, the remote con-
trol is only required for the
start-up.
▶
Starting with the master, use the
on/off switch to switch on all of the
ventilation units in the ventilation sys-
tem in sequence. If an optional VAZ
CPC control is provided, start this up
before switching on the master.
▶
Use the VAZ CPC control or the
VAZ RC remote control to set an
operating mode and the functions.
–
See the operating instructions for
the control or for the remote con-
trol.
Applicability:
VAR 60/1 DW
▶
Use the VAZ RCW remote control to
set up all of the ventilation units in the
system as either masters or slaves.
–
See the operating instructions for
the remote control.
▶
Use the on/off switch to switch on all
of the ventilation units in the ventila-
tion system. If an optional VAZ CPCW
control is provided, this must be con-
figured as the master.
▶
Use the VAZ CPCW control or the
VAZ RCW remote control to set an
operating mode and the functions.