Vaillant PFGHRD A5 - 12/12

- 2 -

Explanation of symbols

 

 

Symbol that denotes danger:   

 

- Imminent danger to life 

 

 

- Risk of severe personal injury  

 

- Risk of minor personal injury

The PFGHRD is an integral part of the flue system 

and as such should be fitted in accordance with 

the manufacturer's flue instructions.

 

Product description

The PFGHRD (Passive Flue Gas Heat Recovery 

Device) is designed as a complimentary energy 

saving system that can be connected to a 

condensing combination boiler. This appliance 

recovers latent energy from flue gases produced 

by condensing combination boilers. The energy 

from flue gases is used to preheat incoming 

domestic cold water. The PFGHRD heat exchanger 

increases domestic hot water efficiency and 

therefore reduces gas consumption, CO

2

 

emissions and waste of sanitary water.

The PFGHRD is included in SAP Appendix Q, under 

Passive Flue Gas Heat Recovery Devices.

Vaillant - PFGHRD 60/100

Contents of package

1.  PFGHRD unit

2.  Support bracket

3.  Wall fixing screws

4.  Unit fixing screws

5.  Installation manual

6.  SAP label (attached to product)

7.  Wall template

8.  Flue anchor bracket (attached to product)

Technical information

DHW system
Max. water pressure
Min. operating pressure

10.0* bar
 0.2 bar

* Use a pressure-
reducing device 
to achieve this, if 
necessary.

Connections
Water connections

15 mm

General dimensions
Height
Width
Depth

276 mm
376 mm
262 mm

Weights
Empty
Full

6.6 kg
9.4 kg

Boiler applications
Condensing boilers only

ecoTEC plus
ecoTEC pro 

Flue Connections (60/100)
Top
Bottom

60 - 100 mm
60 - 100 mm

General
DHW Heat exchanger
Inner casing

Outer casing
Water content

Stainless steel
PP According to 
EN 14471-1
ABS
2.8 litres

a

INSTALLATION

Summary of Contents for PFGHRD 60

Page 1: ...Installation instructions For the installer GB IE Installation instructions PFGHRD 60 100 Passive Flue Gas Heat Recovery Device ...

Page 2: ...re reduces gas consumption CO2 emissions and waste of sanitary water The PFGHRD is included in SAP Appendix Q under Passive Flue Gas Heat Recovery Devices Vaillant PFGHRD 60 100 Contents of package 1 PFGHRD unit 2 Support bracket 3 Wall fixing screws 4 Unit fixing screws 5 Installation manual 6 SAP label attached to product 7 Wall template 8 Flue anchor bracket attached to product Technical inform...

Page 3: ...priate flue system arrangement see 3 Installation diagram In situations where the water pressure exceeds 10 bar it should be reduced to the permitted water pressure To allow pipework to be installed behind the boiler we recommend the use of the 308650 spacing frame No requirement for expansion vessel or mixing valve see Commissioning page 7 PFGHRD Installation 1 The hot and cold water pipes are po...

Page 4: ...Vaillant PFGHRD A5 12 12 4 466 434 384 35 recoFLUE Trim ring Measurement from top of air intake Air intake Flue adaptor 3 Installation diagram INSTALLATION ...

Page 5: ... the flue centreline to any surface below to allow for installation of the boiler 2 Mark and drill holes for the PFGHRD and boiler mounting brackets all as per the wall template Mark the centre of the flue Remove the wall template and drill the flue hole Note that if you intend to use a spacing frame use the information provided with the spacing frame to drill additional holes as required 3 Secure...

Page 6: ...can be combined with stainless steel 7 Connect the flue system to the PFGHRD in accordance with the boiler installation instructions Ensure the flue clamps are fitted and secured Ensure that the flue anchor bracket attached to the PFGHRD is secured to the flue system by the screw provided 8 Note that the overall flue length should not exceed the figures shown in the table on page 3 to allow for th...

Page 7: ...mains water heated by the ecoTEC range of combination boilers will be classed as Category 2 fluid potable water and small expansion volumes created during warm up must be allowed to flow back into the supply pipe No back flow prevention is necessary with this appliance as the very small expansion volume is unlikely to heat the incoming service pipe above 25 Deg C Note that where back flow preventi...

Page 8: ...0020 _00 GBIE 052012 Subject to change Manufacturer Supplier ...

Reviews: