Ventilation boost

Op. mode

Ventilation boost

Menu

Basic settings

Operating mode

ZONE1

Ventilation boost

If you want to switch off the zone while the living areas
are being ventilated, activate the

Ventilation boost

ad-

vanced function.

This advanced function switches the zone off for 30 minutes.
The frost protection function is activated, and hot water gen-
eration and circulation remain active.

Ventilation is activated and works at the highest ventilation
level.

The advanced function is automatically deactivated after 30
minutes or you can cancel the advanced function first. The
heating installation will then return to the pre-set operating
mode.

5.4.5

Party

Op. mode

Party function

Menu

Basic settings

Operating mode

ZONE1

Party function

If you want to switch on the zone, hot water generation,
ventilation and circulation temporarily, activate the

Party

function

advanced function.

The advanced function brings the room temperature to the
set desired temperature

Day

, in accordance with the set time

periods.

The advanced function is deactivated after six seconds or
if you cancel it before the six seconds is up. The heating
installation will then return to the pre-set mode.

5.4.6

Cylinder boost

Op. mode

Cylinder boost

If you have switched off hot water generation or require
hot water outside a time period, activate the

Cylinder

boost

advanced function.

The advanced function heats the water in the domestic hot
water cylinder until it reaches the set desired temperature

Domestic hot water

. The advanced function is active for

one hour unless you cancel it sooner. The heating installa-
tion then returns to the preset operating mode.

5.4.7

System OFF (frost protection active)

Op. mode

System OFF active

The heating function, hot water circuit and cooling are
switched off. The frost protection function is activated.

The circulation is switched off.

Ventilation is activated and works at the lowest ventilation
level.

5.5

Messages

5.5.1

Maintenance message

Overview of maintenance messages (

Appendix C)

If maintenance is required, the control displays a mainten-
ance message in the display.

To prevent the heating installation from breaking down and
to prevent damage, you must pay attention to the mainten-
ance message:

If the operating instructions for the unit that is shown con-
tain a maintenance instruction regarding the maintenance
message, carry out the maintenance work in accordance
with the maintenance instruction.

If the operating instructions for the unit that is shown do
not contain maintenance instructions for the maintenance
message, or if you do not want to carry out the mainten-
ance work yourself, inform a competent person.

5.5.2

Fault message

Overview of fault messages (

Appendix B)

If a fault occurs in the heating installation, the controller dis-
plays a fault message in the display. The competent person
must clear or rectify the fault in the heating installation, oth-
erwise it could cause material damage or make the heating
installation malfunction.

Inform a competent person.

If you would like to see the basic display on the display
again, press the left-hand selection button

Back

.

You can read the current fault messages under

Menu

In-

formation

System status

Fault status

. As soon as a

fault message occurs for the heating installation, the setting
level displays the value

Fault list

. The right-hand selection

button has been assigned the

Display

function.

6

Troubleshooting

Overview of the troubleshooting (

Appendix B)

6.1

Temporarily setting limp home mode

If the fault message

Restricted operation/ comfort pro-

tection Inactive

appears on the display, the heat pump has

failed and the controller enters limp home mode. The auxili-
ary heater now supplies the heating installation with heating
energy. During installation, the competent person has restric-
ted the temperature for limp home mode. You can feel that
the hot water and heating are not becoming very hot.

While you wait for the competent person to come, you can
use the rotary knob to implement the following settings:

Inactive

: The controller works in limp home mode; heating

and hot water at a moderately warm temperature

Heating

: The auxiliary heater takes over heating mode; hot

heating, cold hot water

DHW

: The auxiliary heater takes over domestic hot water

mode; hot water hot, heating cold

DHW+heat.

: The auxiliary heater takes over heating and

domestic hot water mode; heating and hot water hot

Summary of Contents for multiMATIC VRC 700

Page 1: ...perating instructions multiMATIC VRC 700 5 BE fr CH fr FR Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaillant de ...

Page 2: ...al number 6 3 9 CE label 6 4 Operation 6 4 1 Operating structure 6 4 2 Basic display 7 4 3 Operating concept 8 5 Operating and display functions 10 5 1 Information 10 5 2 Settings 12 5 3 Operating modes 16 5 4 Advanced functions 17 5 5 Messages 18 6 Troubleshooting 18 6 1 Temporarily setting limp home mode 18 7 Care 19 7 1 Caring for the product 19 8 Decommissioning 19 8 1 Decommissioning the prod...

Page 3: ...ut by children unless they are supervised Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any direct commercial or industrial use is also deemed to be improper Caution Improper use of any kind is prohibited 1 3 General safety information 1 3 1 Danger caused by improper operation Improper operation may present ...

Page 4: ...Safety 4 Operating instructions multiMATIC 0020255037_00 contain substances that are hazardous to human health and the environment In this case dispose of the batteries at a collection point for batteries ...

Page 5: ... a weather compensator with an outdoor tem perature sensor that is fitted in the open air The control is connected to the outdoor temperature sensor and the heat generator The control controls the heating installation and other connected components e g the do mestic hot water generation for a connected domestic hot water cylinder or the ventilation of a connected ventilation unit 3 2 1 Heating The...

Page 6: ...protects the heating system and apartment from frost damage The frost protection function monitors the outside temperature If the outside temperature falls below 4 C the controller switches the heat gener ator on after a frost protection delay time and brings the target room temperature to 5 C rises above 5 C the controller does not switch the heat generator on but monitors the outside temperature...

Page 7: ...on of the left hand selection button 7 Desired setting 8 Symbol for Auto operat ing mode 9 Mode for the current operating mode The basic display appears Depending on which level you are in you must press the left hand selection button several times If the control is in a selection level or setting level and you do not operate the control for more than 5 minutes 4 2 1 Preferred zone in the basic di...

Page 8: ...he control becomes inoperative and dashes appear on the display instead of values If you do not operate the controller during a period of more than 5 minutes the basic display appears again 4 3 1 Using the rotary knob to make settings in the basic display If the display shows the basic display you can use the rotary knob to change the desired setting The setting that you change depends on the sele...

Page 9: ...he left hand selection button Menu The controller switches to selection level 1 Menu Information Desired temperatures Timer programmes Back Select 3 Turn the rotary knob until the list entry Basic settings is highlighted Menu Planning days away from home Planning days away from home Days at home scheduling Basic settings Basic settings Back Select 4 Press the right hand selection button Select The...

Page 10: ... the heating installa tion s operating mode Standby The heating installation has no energy require ment and is in standby Heat mode The heating installation heats the living areas to the Desired heating temp Cooling The heating installation cools the living areas to the Desired cooling temp DHW The heating installation heats the hot water in the cylinder to the desired temperature Domestic hot wat...

Page 11: ...hat is displayed and the actual energy consumption or energy yield may be significant The specifications for the energy consumption or energy yield are not suitable to be used to create or compare energy billing 5 1 2 1 Consumption Some components do not support the calculation of con sumption the total of which is shown on the display In the instructions for the components you can find out if and...

Page 12: ...played in the top right 5 1 3 Read competent person contact details Menu Information Contact details If the competent person entered their company name and telephone number when they installed the product you can read this data under Contact details 5 1 4 Reading the serial number and article number Menu Information Serial number Serial number shows the serial number of the control ler which the c...

Page 13: ...he time periods the controller brings the room tem perature to the set Set back temp heat 5 2 3 4 Setting time programmes quickly If for example you require different time periods for just one working day in the week first set the times for the entire block Monday Friday Then set the different time period for the working day 5 2 3 5 Displaying and changing different times in the block Monday Sunda...

Page 14: ...y offers one tariff you do not need to set any time periods The cost for the electricity is calculated using one tariff Setting costs Page 15 5 2 4 Days away from home scheduling Menu Days away from home scheduling You can use this function to set a period of time and a temperature for the days that you are away from home System operation during the set time period The hot water is not being heate...

Page 15: ...ed display You can use this function to choose whether you see the data for heating cooling or ventilation in the basic display 5 2 12 Setting costs You must specify all tariffs in the unit of currency per kWh for the calculation to be correct If your energy supply company specifies the gas and elec tricity tariff in the unit of currency per m 3 ask for the precise gas and electricity tariff in th...

Page 16: ... activated directly from any operating mode using the right hand selection button Op mode If the heating installation is equipped with more than one zone the activated operating mode only applies for the zone that was preset by the competent person If more than one zone is activated you can set a separate operating mode for each zone using the left hand selection button Menu Basic settings The pat...

Page 17: ...t operating mode 5 4 Advanced functions The advanced functions can be activated directly from any operating mode using the right hand selection button Op mode If the heating installation is equipped with more than one zone the activated advanced function only applies for the zone that was preset by the competent person If more than one zone is activated you can set a separate advanced function for...

Page 18: ...s a mainten ance message in the display To prevent the heating installation from breaking down and to prevent damage you must pay attention to the mainten ance message If the operating instructions for the unit that is shown con tain a maintenance instruction regarding the maintenance message carry out the maintenance work in accordance with the maintenance instruction If the operating instruction...

Page 19: ... être montée dans un de nos appareils la garantie Vaillant se verait automatiquement annulée 3 Afin que la garantie puisse prendre effet la fiche de garantie dûment complète signée et affranchie doit nous être retournée au plus tard quinze jours après l installation La garantie n est pas d application si le mauvais fonc tionnement de l appareil serait provoqué par un mauvais réglage par l utilisat...

Page 20: ...illant sont raccordés dimensionnement du produit inapproprié aux cara ctéristiques de l installation conditions de transport ou de stockage inappropriées usage anormal des produits ou des installations auxquelles ils sont reliés dysfonctionnement d une pièce de rechange non com mercialisée par le constructeur environnement inapproprié au fonctionnement normal des produits en ce compris caractérist...

Page 21: ...ive A 2 End user level The description of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Fault status Current value No fault Fault list Green IQ Off On On Water pressure Current value bar System status Current value Standby Heat mode Cool ing DHW Burner Current value On off Collector t...

Page 22: ...e last month kWh Fuel Total value for the last month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Consumption History Heating Electricity Total value since start up kWh Fuel Total value since start up kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Solar yield Bar chart Previous yea...

Page 23: ...pending on the ventilation unit Time programmes ZONE1 Heating Time programmes ZONE1 Cooling Time programmes Circulation Time programmes Ventilation Individual days and blocks Monday Tuesday Wednes day Thursday Friday Sat urday Sunday and Monday Friday Saturday Sunday Monday Sunday Mo Fr 06 00 22 00 Sa 07 30 23 30 Su 07 30 22 00 Period 1 Start End Period 2 Start End Period 3 Start End 00 00 24 00 h...

Page 24: ...ear 01 01 15 Time 00 00 23 59 h min 00 10 08 00 Daylight saving time Manual Auto Manual Basic settings Display Display contrast 1 15 1 9 Button lock off On off Preferred display Heating Cooling Vent Heating Basic settings Costs Tariff for aux heater 1 999 1 12 Low tariff elec rate 1 999 1 16 High tariff elec rate 1 999 1 20 Basic settings Offset Room temperature 3 0 3 0 K 0 5 0 0 Outside temperatu...

Page 25: ...ew Restricted opera tion comfort protection insuf ficient heating up of the heating and the domestic hot water Heat pump does not work 1 Inform the competent person 2 Select the setting for limp home mode until the competent person arrives 3 Read the Temporarily setting limp home mode Page 18 function for more details Display view Fault F Fault Heat generator 1 the specific fault code e g F 33 and...

Page 26: ...he operating instructions for the ventilation unit 4 Low water pres sure The water pressure in the heat ing system is too low Refer to the operating instruc tions for the relevant heat gen erator for information on filling with water See the operating instructions for the heat generator 5 Service date Next service on The competent person has entered a date on which main tenance is due for the heat...

Page 27: ...splay 7 Outside temperature setting the offset 15 P Party 18 Preventing a malfunction 6 R Reading the article number 6 12 Reading the electrical consumption 12 Reading the environment yield 12 Reading the fuel consumption 12 Reading the heat recovery yield 12 Reading the serial number 6 12 Reading the solar statistics 12 Reading the system status 10 Restoring the language 14 Room temperature setti...

Page 28: ...0255037_00 T Time period deviating times in the block 13 Time programme quick setting 13 Setting 13 Time programme after switching off the voltage 13 V Ventilation 5 Ventilation boost 18 Ventilation level 12 Z Zone 6 12 Zone in the basic display 7 ...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...ntendienst 2 3349352 info vaillant be www vaillant be Vaillant Sàrl Rte du Bugnon 43 CH 1752 Villars sur Glâne Tél 026 40972 10 Fax 026 40972 14 Service après vente tél 026 40972 17 Service après vente fax 026 40972 19 romandie vaillant ch www vaillant ch N V Vaillant S A Golden Hopestraat 15 B 1620 Drogenbos Tel 2 3349300 Fax 2 3349319 Kundendienst Service après vente Klantendienst 2 3349352 info...

Reviews: