Set-up 4
0020264435_00 electronicVED Installation instructions
7
4.4.2
Removing the product casing
X9
4
2
3
5
1
1.
Grip the two straps
(1)
on the panel
(2)
.
2.
Splay the two straps (pull them away from the product).
3.
Remove the panel
(2)
.
4.
Undo the two screws
(3)
.
5.
Fold up the cover
(4)
.
6.
Pull the temperature selector plug from the electronics
(slot X9) in the product
(5)
.
7.
Remove the cover
(4)
from the product.
4.4.3
Installing the product
390
277
85
85
1
2
2
1
1.
Hold the installation template against the wall and mark
the fixing points.
–
Product alignment: Vertically on the wall
Note
When replacing a product, you can use the
drill holes from the previous installation
provided these are compatible with the
additional holes in the installation plate.
2.
Use rawl plugs and screws to secure the installation
plate
(1)
to the fixing points
(2)
.
Danger!
Risk of electric shock caused by penetrat-
ing water
The cable duct prevents water from pen-
etrating along the mains connection cable
and into the product. If the cable duct is com-
pletely cut away, water can very easily penet-
rate and damage the product and may cause
a potentially lethal electric shock.
▶
Never cut off the cable duct completely.
▶
Cut the end of the cable duct in such a
way that the sleeve tightly surrounds the
mains connection cable.
3.
Fold the cable duct up or down depending on the loca-
tion of the mains connection cable.
4.
Feed the cable through the cable duct and into the pro-
duct's interior.