4 Operation
8
Operating instructions ecoVIT exclusiv 0020258609_00
4.2.3
Switching off the product
1
2
1
Main switch
2
Display
▶
Use the main switch
(1)
to switch off the product.
◁
0
: "OFF"
Note
In order for the protection modes, such as
frost protection, to remain activated, only ac-
tivate and deactivate the product using the
control (you can find information about this in
the relevant operating instructions). If no con-
trol is present, block the heating and cylinder
charging mode by turning the dial to the anti-
clockwise end stop.
4.3
Setting the language
▶
Contact your competent person so that they can set the
correct language for the control panel.
4.4
Setting the heating flow temperature
Conditions
: Control connected
2
1
1
Main switch
2
Heating flow temperat-
ure rotary knob
▶
Turn the rotary knob for the heating flow temperature
(2)
as far as it will go clockwise.
◁
The heating flow temperature is automatically set by
the control.
Note
To ensure that the control can set temper-
atures up to the maximum heating flow
temperature, the rotary knob for the heating
flow temperature should always be set to the
clockwise end stop.
Conditions
: No control connected
2
1
1
Heating flow temperat-
ure rotary knob
2
Displaying the current
heating flow temperat-
ure
▶
Set the target flow temperature on the rotary knob for
the heating flow temperature
(1)
in accordance with the
outdoor temperature.
Position
Meaning
Outdoor temperat-
ure
Fully left
Frost protection
Anti-clockwise (but
not at the end stop)
Transition Time
Approx.
10 … 20
℃
Centre
Moderate cold
Approx.
0 … 10
℃
Clockwise
Extreme cold
Below
0
℃
◁
After turning the rotary knob for the heating flow tem-
perature, the display shows the set target flow tem-
perature
(2)
. After three seconds, this display goes
out and the default display reappears (current heat-
ing flow temperature).
Note
The maximum heating flow temperature is set
in the factory at 75 °C. This can be defined by
the competent person to be between 40 °C
and 85 °C.