6 Start-up
16
Installation and maintenance instructions ecoTEC plus 0020214491_01
5.6.6
Connecting a low loss header sensor
1.
Connect the low loss header sensor to the edge con-
nector X41 at terminal RF or to the controller. When do-
ing so, observe the instructions for the controller.
2.
Plug the edge connector into the PCB slot X41.
3.
Activate the low loss header function at the controller.
5.6.7
Connecting a cylinder charging pump
▶
Connect an external cylinder charging pump (to be fitted
on-site) to the pink ProE plug X6.
5.6.8
Connecting additional components
You can actuate an additional component with the aid of the
auxiliary relay that is installed, and you can actuate two other
components with the multi-functional module.
The following components can be actuated:
1.
Circulation pump
2.
External pump
3.
Cylinder charge pump
4.
Extractor hood
5.
External solenoid valve
6.
External fault signal
7.
Not active
8.
eBUS remote control (not active)
9.
Legionella protection pump (not active)
10. Not active.
5.6.8.1 Using the auxiliary relay
1.
Connect an additional component directly to the integ-
rated auxiliary relay using the grey plug on the PCB.
2.
Carry out the wiring. (
→
Page 15)
3.
To start up the connected component, select the
component via
D.26
, see Calling up diagnostics codes
(
→
Page 23).
5.6.8.2 Using the VR 40 ("2 in 7" multi-functional
module)
1.
Install the components in accordance with the respect-
ive instructions.
2.
Select
D.27
(
→
Page 23) to actuate relay 1 on the multi-
functional module.
3.
Select
D.28
(
→
Page 23) to actuate relay 2 on the multi-
functional module.
5.6.9
Actuating the circulation pump according
to requirements
Note
The product's electronics provide the opportunity
to control a domestic hot water cylinder's circula-
tion pump as necessary (similar to an automatic
light unit for stairs). It is controlled using an ex-
ternal button (to be fitted on-site) that can be in-
stalled anywhere in the dwelling, e.g. in the bath-
room or kitchen. When the button is pressed, the
circulation pump starts up. The pump is switched
on again after five minutes. Several buttons can
be pressed in parallel. Irrespective of the external
control of the circulation pump, the "Control by
programmable time periods" function continues to
be possible when a controller is used.
Conditions
: Domestic hot water cylinder connected
▶
Carry out the wiring. (
→
Page 15)
▶
Connect the supply line for an external button using ter-
minals 1
(0) and 6 (functional drawing) on the X41
edge connector, which is supplied with the controller.
▶
Plug the edge connector into the PCB slot X41.
6
Start-up
6.1
Carrying out the initial start-up
Initial start-up must be carried out by a customer service
technician or an authorised competent person using the
commissioning checklist. The commissioning checklist in the
appendix (
→
Page 39) of the installation instructions must be
filled in and stored carefully along with the unit's documenta-
tion.
▶
Carry out the start-up procedure using the commissioning
checklist in the appendix.
▶
Fill in and sign the commissioning checklist.
6.2
Switching on the product
▶
Set the product's main switch to
1
.
◁
The basic display appears on the display.
6.3
Using check programmes
By activating various check programmes, you can trigger
special functions on the product.
Display
Meaning
P.0
Purging check programme:
The internal pump is cyclically actuated.
The heating circuit and the hot water circuit are
purged via the automatic air vent (the cap of the
automatic air vent must be released).
1 x
: Start heating circuit purging (display view:
HP)
2 x
: Start cylinder charging circuit purging
(display view: SP)
3 x
: Exit purging programme
Note
The purging programme runs for 6.5 minutes per
circuit and then terminates.