5
Outdoor temperature sensor, flow temperature
sensor (optional, external), DCF receiver
6
Circulation pump remote control
7
Power coding resistor
8
Return temperature sensor
9
Flow temperature sensor
10
Fan
11
Surface-mounted thermostat/burner off
12
24 V DC room thermostat
13
Bus connection (digital room thermostat/control)
14
Prioritising diverter valve
15
Water pressure sensor
16
Cylinder temperature sensor
17
Cylinder contact "C1/C2"
18
Gas group coding resistor
19
Additional relay (select via D.026)
20
Internal pump
21
Ignition electrode
*
Depending on product type