7.12.6.1 Using the auxiliary relay
1.
Connect an additional component directly to the integ-
rated auxiliary relay using the grey plug on the PCB.
2.
Carry out the wiring.
3.
To start up the connected component, select the com-
ponent in diagnostics code
D.026
. (
7.12.6.2 Using the VR 40 ("2 in 7" multi-functional
module)
1.
Install the components in accordance with the respect-
ive instructions.
Condition
: Components connected to relay 1
▶
Activate
D.027
. (
Condition
: Components connected to relay 2
▶
Activate
D.028
. (
7.12.7 Actuating the circulation pump according to
requirements
1.
Carry out the wiring.
2.
Connect the connection cable for the external button
using terminals 1
(0) and 6 (FB) on the X41 edge
connector, which is supplied with the control.
3.
Plug the edge connector into the PCB slot X41.