Replacing components
78
Installation and maintenance instructions ecoTEC plus 0020116700_01
14
14.8.1 Replacing either the display or the PCB
>
Replace the PCB or display according to the assembly
and installation instructions supplied.
230V~
230V~
N
L
Burner
off
24V=
RT
- +
BUS
Burner
off
2
1
14.14
Coding resistance
i
If you replace the PCB, you must remove the
front left coding resistor (
1
) (plug X24) on the
old PCB and insert it into the new PCB.
If you are replacing only one of the two components (PCB
or display), the parameter matching functions automati-
cally. By switching on the boiler, the new component takes
over the previously set parameters from the unreplaced
component.
14.8.2 Replacing the PCB and the display at the
same time
Setting the language and appliance type
i
If you are replacing both components, you must
detach the coding resistor (
¬ fig. 14.14, pos. 1
)
(plug X24) at the front left from the old PCB and
plug it into the new PCB.
Language
02 English
Cancel
Ok
14.15 Setting the language
If you are replacing both components at the same time
(spare part case), the boiler switches directly to the menu
for selecting the language after switching on. The default
language setting is English. You can select the language
that you require using the minus and plus buttons and con-
firm with OK.
You are then automatically taken to the appliance type set-
ting D.093.
>
Select the correct value for the relevant appliance type
in accordance with
¬ table 14.1
.
After confirmation, the display restarts itself automatically
and then starts the installation assistant.
ecoTEC plus
Device specific
number
612 (VU GB 126/5-5)
1
615 (VU GB 156/5-5)
3
618 (VU GB 186/5-5)
4
624 (VU GB 246/5-5)
9
630 (VU GB 306/5-5)
14
637 (VU GB 376/5-5)
20
824 (VUW GB 246/5-5)
6
831 (VUW GB 316/5-5)
10
837 (VUW GB 376/5-5)
17
14.1
Device specific numbers for the appliance types
The electronics are now set to the appliance type and the
para meters of all adjustable diagnosis codes are set to fac-
tory settings.
>
Make the system-specific settings (