background image

3 Product description

6

Operating instructions ecoTEC exclusive 0020193967_01

if you press a button while the product is switched on.
At first, pressing this button does not trigger any other
function.

The light goes out after one minute if you do not press any
button.

3.4

Displayed symbols

Symbol

Meaning

Explanation

Burner operating cor-
rectly

Burner on

Current burner modula-
tion rate

bar

Current filling pressure of
the heating system
The dashed lines show
the permitted range.

Permanently on:
Filling pressure in
the permitted range.

Flashing: Filling
pressure outside
the permitted range.

Hot water generation
active

Permanently on:
Draw-off mode be-
fore burner is on

Flashing: Burner on
in draw-off mode

Heating mode active

Permanently on:
Heating mode heat
requirement

Flashing: Burner on
in heating mode

Green iQ mode active

Permanently on:
Energy-saving mode
active

Maintenance required

Information on mainten-
ance message in the
"Live Monitor".

Summer mode active
Heating mode is
switched off

Burner anti-cycling time
is active

To avoid the need for
frequent switching on
and off (increases the
product's working life).

F.XX

Fault in the product

Appears instead of the
basic display, may be
an explanatory plain text
display.

3.5

Information on the identification plate

The identification plate is mounted on the underside of the
product in the factory.

Applicability:

Product with integrated hot water generation

OR Product with integrated hot water generation

Information on the
identification plate

Meaning

Read the instructions.

VU(W) ...

Type designation

..6/5-7

Calorific value power/product generation
equipment

ecoTEC exclusive

Product description

Information on the
identification plate

Meaning

2H, G20

20 mbar

(2.0 kPa)

Gas group and gas connection pressure
as set at the factory

ww/yyyy

Date of manufacture: Week/year

Cat.

Approved unit categories

Types

Approved gas-fired units

PMS

Permissible total overpressure in heating
mode

PMW

Permissible total overpressure during hot
water generation

T

max.

Max. flow temperature

ED 92/42

Current efficiency directive fulfilled with
4* rating

V Hz

Mains voltage and mains frequency

W

Max. electrical power consumption

IP

Level of protection

Heating mode

Hot water generation

P

Nominal heat output range

Q

Heat input range

D

Nominal hot water draw-off rate

Bar code with serial number,
7th to 16th digit = product article number

3.6

Serial number

The serial number is located on a plate behind the front flap.
The plate is in a plastic fish plate. You can also display the
serial number in the display.

3.7

CE label

The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.

The declaration of conformity can be viewed at the manufac-
turer's site.

3.8

Energy Saving Trust Endorsed Products

Only the most energy efficient products can carry the
‘Energy Saving Trust Endorsed Product’ brandmark making
it easy for consumers to choose products that have met strict
energy performance criteria.

Available for: Boilers, Heating controls and chemical inhib-
itors, the Energy Saving Trust endorsed product brandmark
gives consumers confidence that a product will cost less to
run, help lower energy bills and reduce carbon emissions.

About the Energy Saving Trust

Energy Saving Trust is an independent and impartial organ-
isation that provides trusted energy saving advice to em-

Summary of Contents for ecoTEC exclusive 627

Page 1: ...TEC exclusive 627 VU 256 5 7 H GB 835 VUW 356 5 7 H GB 843 VUW 436 5 7 H GB GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info v...

Page 2: ...e product 8 4 9 Setting the language 8 4 10 Setting the domestic hot water temperature 8 4 11 Switching Comfort mode on and off 8 4 12 Setting the heating flow temperature 8 4 13 Switching Green iQ mo...

Page 3: ...children unless they are supervised Any other use that is not specified in these instructions or use beyond that specified in this document shall be considered improper use Any direct commercial or in...

Page 4: ...y of the product 1 3 7 Risk of poisoning caused by insufficient combustion air supply Conditions Open flued operation Ensure that there is a sufficient combus tion air supply 1 3 8 Risk of corrosion d...

Page 5: ...exclusive 0010017065 47 044 67 3 Product description 3 1 Product design 1 2 3 1 Control elements 2 Plate with serial number on the rear 3 Front flap 3 2 Control elements 50 5 4 3 2 1 1 On off button 2...

Page 6: ...eneration equipment ecoTEC exclusive Product description Information on the identification plate Meaning 2H G20 20 mbar 2 0 kPa Gas group and gas connection pressure as set at the factory ww yyyy Date...

Page 7: ...ls Not pressing any button for longer than 15 minutes If there is an error message present the basic displays switches to the error message 4 3 Menu display Xxxx Xxxxxxxxxxx Xxxx Xxxxxxx Xxxxxxxxxx xx...

Page 8: ...Comfort mode on and off Applicability Product with integrated hot water generation Note Comfort mode immediately supplies hot water at the required temperature without you having to wait for the wate...

Page 9: ...e installation with suf ficient heating water the display automatically disappears after 20 seconds 4 14 2 Filling the heating installation Caution Risk of material damage due to heating water that is...

Page 10: ...nsure that the heating installation remains in operation and that all rooms are sufficiently heated even when you are away Note To keep the frost protection devices active you should switch your produ...

Page 11: ...disposal of the packaging If the product is identified with this symbol In this case do not dispose of the product with the household waste Instead hand in the product to a collection centre for waste...

Page 12: ...op valve The power supply in the building is disconnected Check the fuse in the building The product switches on automatically when the power is restored The product is switched off Switch on the prod...

Page 13: ...ng mode Pump overrun S 08 Heating remaining anti cycling time xx mins S 09 Heating mode Measuring programme Domestic hot water mode products with integrated domestic hot water generation S 10 Domestic...

Page 14: ...Appendix 14 Operating instructions ecoTEC exclusive 0020193967_01 Status code Meaning S 58 Modulation limitation due to noise wind S 76 System pressure too low Top up water...

Page 15: ......

Page 16: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Reviews: