36
5 Commissioning Part I
Instructions for installation and servicing ecoMAX
36
When altering values the display will flash.
4 Press and hold the ”i”–button to save the required
value to memory. When the value is saved, the display
will stop flashing.
5 Diagnostic mode is cancelled as follows:
Press the ”i” and ”+”–buttons simultaneously
or Do not press any key for approximately four minu-
tes. The display will now return to its normal state
(current heating–system flow temperature, e.g. 45°C).
≈
5 sec
Appliance
Maximum net heat input
Maximum gas rate
Maximum gas rate
in kW
Natural gas in m3/h
Propane in kg/h
ecoMAX 613/2 E
13.5
1.43
1.05
ecoMAX 618/2 E
18.4
1.95
1.43
ecoMAX 622/2 E
22.4
2.37
1.74
ecoMAX 635
34.9
3.70
2.70
ecoMAX 824/2 E
23.0
2.43
1.78
ecoMAX 828/2 E
28.0
2.96
2.18
ecoMAX 835 E
35.0
3.70
2.70
Tab. 5.1 Maximum gas rates.
83 41 77_12 GB04.04.qxd 22.09.2004 12:34 Uhr Seite 36