Instructions for Use, Installation and Servicing ecoMAX pro
30
17 Fault finding
No. Description
Comments
18E
28E
Action
1
Central heating maximum output
Set minimum to maximum product output (kW)
18
28
adjustable
2
Flue system pressure loss
No function
adjustable
3
Minimum temperature for
Set minimum temperature
38
38
adjustable
Central Heating
(22°, 28°, 38° or 50°C)
4
Maximum temperature for
Set maximum temperature
80
80
adjustable
Central Heating
(50°, 73° or 80° C)
5
Pump mode selection
1 – When room stat on (continuous)
1
1
adjustable
2 – When burner on (not continuous)
3 – Winter position/under floor heating (continuous)
6
External sensor ‘slope’
No function
adjustable
7
External sensor ‘offset’
No function
adjustable
8
Burner override Gas rate/CO
2
0 – normal
0
0
adjustable
combustion check
1 – burner to Pmin
2 – burner to Pmax
Immediately communicated to the mainboard,
and reset to 0 after 15 minutes
9
Cylinder with NTC
No function – however if altered to ‘1’ = ON fault
adjustable
code 8 will be displayed ‘tank NTC fault’
10
Adaptive heating or night-day switch
No function
adjustable
11
Night-day setpoint (Delta value)
No function
adjustable
12
Central heating flow temperature
°C
Read only
13
Central heating return temperature
°C
Read only
14
Domestic hot water temp.
No function
Read only
15
Tank temp.
No function
Read only
16
DHW flow
No function
Read only
17
Extractor speed
Extractor speed, RPM x 100
Read only
18
Burner demand power
kW
Read only
19
Working phase
No function
Read only
20
External sensor setpoint
No function
Read only
21
User interface version
No function
Read only
22
User interface revision
No function
Read only
23
Product code
Code reference for ecoMAX pro
149
141
Read only
24
Min. fan speed
RPM x 100 (800 – 6,000)
12
12
Read only
25
Max. fan speed
RPM x 100 (2,000 – 6,000)
41
57
Read only
26
Fan speed during ignition
60 – 100%
80
60
Read only
27
Delta
No function
Read only
28
‘Rechauffe’
No function
Read only
29
Running hours
Flame presence hours stored in E2prom every 2hrs
Read only
30
Running hours
Read only
31
Fault memory*
Memory 1
Read only
32
Memory 2
Read only
33
Memory 3
Read only
34
Memory 4
Read only
35
Memory 5
Read only
36
Fault memory reset
Memory can be reset by pressing ‘+’ and
+/-
‘-‘ together