1 Safety

4

Operating instructions ecoFIT sustain 0020277253_00

1.3.4 Risk of death due to blocked or

leaking flue pipework

What to do if you smell flue gas in the prop-
erty:

Open all accessible doors and windows
fully to provide ventilation.

Switch off the product.

Inform a competent person.

1.3.5 Risk of death due to explosive and

flammable materials

Do not use the product in storage rooms
that contain explosive or flammable sub-
stances (such as petrol, paper or paint).

1.3.6 Risk of death due to changes to the

product or the product environment

Never remove, bridge or block the safety
devices.

Do not tamper with any of the safety
devices.

Do not damage or remove any tamper-
proof seals on components.

Do not make any changes:

The product itself

to the gas, supply air, water and electri-
city supply lines

to the entire flue system

to the entire condensate discharge sys-
tem

to the expansion relief valve

to the drain pipework

to constructional conditions that may
affect the operational reliability of the
product

1.3.7 Risk of corrosion damage due to

unsuitable combustion and room air

Sprays, solvents, chlorinated cleaning
agents, paint, adhesives, ammonia com-
pounds, dust or similar substances may lead
to corrosion on the product and in the air/flue
pipe.

Ensure that the combustion air supply is
always free of fluorine, chlorine, sulphur,
dust, etc.

Ensure that no chemical substances are
stored at the installation site.

1.3.8 Risk of material damage caused by

frost

Ensure that the heating installation always
remains in operation during freezing con-
ditions and that all rooms are sufficiently
heated.

If you cannot ensure the operation, have a
competent person drain the heating install-
ation.

1.3.9 Risk of injury and material damage

due to maintenance and repairs
carried out incorrectly or not carried
out at all

Never attempt to carry out maintenance
work or repairs on your product yourself.

Faults and damage should be immediately
rectified by a competent person.

Adhere to the maintenance intervals spe-
cified.

Summary of Contents for ecoFIT sustain 618

Page 1: ...Operating instructions ecoFIT sustain 615 630 GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaillant de ...

Page 2: ...itching on the product 7 4 8 Setting the heating flow temperature 7 4 9 Setting the hot water temperature 8 4 10 Switching off the product s functions 8 4 11 Guaranteeing the correct filling pressure of the heating installation 8 4 12 Protecting the heating installation against frost 9 4 13 Switching the product to standby mode 9 5 Troubleshooting 9 5 1 Detecting and rectifying faults 9 5 2 Callin...

Page 3: ...n unless they are supervised Any other use that is not specified in these in structions or use beyond that specified in this document shall be considered improper use Any direct use in industrial or commercial processes is also deemed to be improper Caution Improper use of any kind is prohibited 1 3 General safety information 1 3 1 Installation by competent persons only The installation inspection...

Page 4: ...the drain pipework to constructional conditions that may affect the operational reliability of the product 1 3 7 Risk of corrosion damage due to unsuitable combustion and room air Sprays solvents chlorinated cleaning agents paint adhesives ammonia com pounds dust or similar substances may lead to corrosion on the product and in the air flue pipe Ensure that the combustion air supply is always free...

Page 5: ...anel 50 1 9 8 7 6 2 3 4 1 5 1 Current heating flow temperature operating mode fault code or additional information 2 Current assignment of the right hand selection button 3 Left and right hand selection buttons 4 and button 5 Reset button 6 Maximum output only used for Austria Ger many and Switzerland 7 Access to the menu for additional information 8 Current assignment of the left hand selection b...

Page 6: ...ling mode Tmax Max flow temperature NOx NOx class for the product Code DSN Specific product code Information on the identification plate Meaning Read the instructions GC no Gas council number 3 5 Serial number The serial number is located on a plastic plate at the bottom of the front casing 3 6 CE label The CE label shows that the products comply with the basic requirements of the applicable direc...

Page 7: ...el contains information and setting options that you require as the end user The installer level is reserved for the competent person It is protected by a code Only competent persons may change any settings in the installer level 4 4 Cabinet type casing Enclosing the product in cabinet type casing requires compli ance with the applicable design instructions If you require cabinet type casing for y...

Page 8: ...20 MPa 1 0 bar and 2 0 bar or lie between the two dashed lines in the bar graph display If the heating installation extends over several storeys a higher filling pressure may be required for the heating installation Ask a competent per son for details In addition the symbol appears after approx one minute If the filling pressure in the heating installation falls below 0 05 MPa 0 5 bar then the pro...

Page 9: ...The display shows OFF and goes out The product is now in standby mode The product s frost protection function is activated The main power supply is not interrupted The product continues to be supplied with power 5 Troubleshooting 5 1 Detecting and rectifying faults If faults occur proceed in accordance with the table in the appendix Troubleshooting Page 11 If the fault cannot be eliminated using t...

Page 10: ...nt person permanently decommission the product 8 Recycling and disposal The competent person who installed your product is re sponsible for the disposal of the packaging If the product is labelled with this mark In this case do not dispose of the product with the household waste Instead hand in the product to a collection centre for waste electrical or electronic equipment If the product contains ...

Page 11: ...omfort protection mode flame loss at minimum load B Troubleshooting Fault Cause Measure Product does not start up No hot water Heating remains cold The gas isolator cock installed on site and or the gas isolator cock on the product is closed Open both gas isolator cocks The power supply in the building is disconnected Check the fuse in the building The product switches on automatically when the po...

Page 12: ...re DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent We reserve the right to make technical changes 0020277253_00 ...

Reviews: