background image

7 Decommissioning

10

Operating instructions ecoFIT sustain 0020277253_00

7

Decommissioning

7.1

Temporarily decommissioning the product

Caution.
Risk of material damage due to frost.

The frost protection and monitoring devices
are only active while the unit is connected
to the power mains and switched on via the
on/off button, and when the gas isolator cock
is open.

Temporarily decommission the product
only if no frost is expected.

Temporarily decommission the product only if no frost is
expected.

Switch off the product via the main switch installed on-
site.

The display goes out.

When decommissioning the product for a prolonged
period (e.g. holiday), close the gas isolator cock and also,
for combination products, the cold water stop valve.

7.2

Permanently decommissioning the product

Have a competent person permanently decommission
the product.

8

Recycling and disposal

The competent person who installed your product is re-
sponsible for the disposal of the packaging.

If the product is labelled with this mark:

In this case, do not dispose of the product with the
household waste.

Instead, hand in the product to a collection centre for
waste electrical or electronic equipment.

If the product contains batteries that are labelled with

this mark, these batteries may contain substances that are
hazardous to human health and the environment.

In this case, dispose of the batteries at a collection point
for batteries.

9

Guarantee and customer service

9.1

Guarantee

For information on the manufacturer's guarantee, you can
write to the contact address that is provided on the back
page.

9.2

Customer service

To ensure regular servicing, it is strongly recommended
that arrangements are made for a Maintenance Agreement.
Please contact Vaillant Service Solutions for further details:

Telephone: 0330

100

3461

Summary of Contents for ecoFIT sustain 618

Page 1: ...Operating instructions ecoFIT sustain 615 630 GB IE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaillant de ...

Page 2: ...itching on the product 7 4 8 Setting the heating flow temperature 7 4 9 Setting the hot water temperature 8 4 10 Switching off the product s functions 8 4 11 Guaranteeing the correct filling pressure of the heating installation 8 4 12 Protecting the heating installation against frost 9 4 13 Switching the product to standby mode 9 5 Troubleshooting 9 5 1 Detecting and rectifying faults 9 5 2 Callin...

Page 3: ...n unless they are supervised Any other use that is not specified in these in structions or use beyond that specified in this document shall be considered improper use Any direct use in industrial or commercial processes is also deemed to be improper Caution Improper use of any kind is prohibited 1 3 General safety information 1 3 1 Installation by competent persons only The installation inspection...

Page 4: ...the drain pipework to constructional conditions that may affect the operational reliability of the product 1 3 7 Risk of corrosion damage due to unsuitable combustion and room air Sprays solvents chlorinated cleaning agents paint adhesives ammonia com pounds dust or similar substances may lead to corrosion on the product and in the air flue pipe Ensure that the combustion air supply is always free...

Page 5: ...anel 50 1 9 8 7 6 2 3 4 1 5 1 Current heating flow temperature operating mode fault code or additional information 2 Current assignment of the right hand selection button 3 Left and right hand selection buttons 4 and button 5 Reset button 6 Maximum output only used for Austria Ger many and Switzerland 7 Access to the menu for additional information 8 Current assignment of the left hand selection b...

Page 6: ...ling mode Tmax Max flow temperature NOx NOx class for the product Code DSN Specific product code Information on the identification plate Meaning Read the instructions GC no Gas council number 3 5 Serial number The serial number is located on a plastic plate at the bottom of the front casing 3 6 CE label The CE label shows that the products comply with the basic requirements of the applicable direc...

Page 7: ...el contains information and setting options that you require as the end user The installer level is reserved for the competent person It is protected by a code Only competent persons may change any settings in the installer level 4 4 Cabinet type casing Enclosing the product in cabinet type casing requires compli ance with the applicable design instructions If you require cabinet type casing for y...

Page 8: ...20 MPa 1 0 bar and 2 0 bar or lie between the two dashed lines in the bar graph display If the heating installation extends over several storeys a higher filling pressure may be required for the heating installation Ask a competent per son for details In addition the symbol appears after approx one minute If the filling pressure in the heating installation falls below 0 05 MPa 0 5 bar then the pro...

Page 9: ...The display shows OFF and goes out The product is now in standby mode The product s frost protection function is activated The main power supply is not interrupted The product continues to be supplied with power 5 Troubleshooting 5 1 Detecting and rectifying faults If faults occur proceed in accordance with the table in the appendix Troubleshooting Page 11 If the fault cannot be eliminated using t...

Page 10: ...nt person permanently decommission the product 8 Recycling and disposal The competent person who installed your product is re sponsible for the disposal of the packaging If the product is labelled with this mark In this case do not dispose of the product with the household waste Instead hand in the product to a collection centre for waste electrical or electronic equipment If the product contains ...

Page 11: ...omfort protection mode flame loss at minimum load B Troubleshooting Fault Cause Measure Product does not start up No hot water Heating remains cold The gas isolator cock installed on site and or the gas isolator cock on the product is closed Open both gas isolator cocks The power supply in the building is disconnected Check the fuse in the building The product switches on automatically when the po...

Page 12: ...re DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer s written consent We reserve the right to make technical changes 0020277253_00 ...

Reviews: