Vaillant ecoCRAFT VKK GB 1206/2-E-H Operating Manual Download Page 7

7

Operating manual

 ecoCRAFT

4.2 

Overview of the operating field

9

8

7

6

5

4

3

2

1

Fig. 4.1  Controls

The operating elements have the following functions:

1/2

 

+/- buttons: After the parameters have been 
called up, the buttons "+" and "-" are used to 
change the individual values.

3

 

OK button: All changes must be stored by pushing 
the OK button. The storing is confirmed by the 
figures flashing.

4

 

Information button - i: After calling up the 
required mode, the individual parameters of the 
specific mode can be called up by briefly pushing 
the i-button.

5

 

Reset button: A malfunction, indicated by a 
flashing read-out on the display, is reset by 
pushing the reset button. If the fault reappears, 
then customer service must be informed.

6

 

Display for indication of the current operating 
mode, the menu level or specific additional 
information

7

 

Mode button for selection of the various menu 
levels.

8

 

Interlock displays for the individual burner 
modules (fault resolution see Chapter 5.1).

9

 

Button for switching the unit on and off

4.3 

Switching the unit on and off

1

Fig. 4.2  Switching the unit on and off

 Caution!

The mains switch may only be actuated if the 
heating installation is properly filled with water. 
If this is not complied with, damage to the 
pump and heat exchanger may occur.

Use the switch (

1

) to switch the appliance on and off:

When the button (

1

) is depressed and is lit up, the unit is 

switched on and has a power supply.

When the button (

1

) is not depressed and is not lit up, 

the unit is switched off and is isolated from the mains.

 Caution!

The frost protection and monitoring devices are 
only active if the mains switch of the unit is 
depressed and shows a green light.

In order not to switch off this safety device, you should 
switch your heating unit on and off using the regulator. 
Information concerning this will be found in the relevant 
operating manual.

 Note!

For longer periods out of commission (e.g. for 
building renovation work) you should turn the 
gas valve off. In this connection, please refer to 
the instructions in Chapter 2 concerning frost 
protection.

Operation 4

Summary of Contents for ecoCRAFT VKK GB 1206/2-E-H

Page 1: ...For the owner VKK GB 806 2 E H VKK GB 1206 2 E H VKK GB 1606 2 E H VKK GB 2006 2 E H VKK GB 2406 2 E H VKK GB 2806 2 E H Operating manual ecoCRAFT Modular Gas Condensing Boiler GB...

Page 2: ...e accept no liability for any damage caused by failure to observe these instructions Other applicable documents All operating manuals of structural parts and components of the installation must be obs...

Page 3: ...rations to structural elements in the vicinity of the appliance which might affect its operational safety For example Keep all openings for air and flue gas free Make sure for example that any tempora...

Page 4: ...ecoCRAFT units are state of the art appliances which have been constructed in accordance with recognised safety regulations Nevertheless there is still a risk of death or serious injury to the user o...

Page 5: ...to summer mode The heating mode is then shut off however the device or the plant remains ready for operation for water heating Uniform heating Often in an apartment with central heating only one room...

Page 6: ...mes can be set using timers which most circulation pumps have fitted to them or with which they can be retro fitted Weather compensators often have ancillary functions for controlling circulation pump...

Page 7: ...ult resolution see Chapter 5 1 9 Button for switching the unit on and off 4 3 Switching the unit on and off 1 Fig 4 2 Switching the unit on and off Caution The mains switch may only be actuated if the...

Page 8: ...operational condition of your unit The operation codes 1 2 and 5 appear at the start of each individual module The number of the individual module is preset on the operational display The following di...

Page 9: ...ory setting max Call ups and settings Setting Display Store set value with OK Factorysettingmaynot bechanged Operation mode ParameterNo ParameterNo ParameterNo Factorysettingmaynot bechanged Hotwater...

Page 10: ...C in the parameter level under point 3 Caution None of the other settings in the parameter level can be changed to avoid malfunctions 4 6 Diagnosis mode In the diagnosis mode you can have the individu...

Page 11: ...fault resolution button 1 on the operating field The faults on the boiler can be resolved as follows First reset the relevant module by pushing the corresponding red module reset button 1 on the opera...

Page 12: ...itch integrated in the unit which prevents the unit from starting up if the system pressure 0 2 bar This is shown in the display as E26 At water pressures 0 8 bar the fault display disappears If the h...

Page 13: ...peration of your boiler it is recommended that regular servicing is carried out by your service provider Vaillant Applied System Sales Vaillant Ltd Unit D1 Lowfields Business Park Elland West Yorkshir...