Both your Valliant ecoCRAFT gas heating boiler and its 
packaging consist mainly of recyclable raw materials.

3.4.1 Appliance

Make sure the old appliance and any accessories are 
disposed of properly.

3.4.2 Packaging

Please leave the disposal of the transport packaging to 
the qualified servicing company which installed the 
appliance.

 Note!

Please observe the applicable national legal 
regulations.

3.5 Energy 

saving 

tips

Installing a weather compensator

Weather compensators regulate the heating supply 
temperature according to the outside temperature. No 
more heat is created than is required. The designated 
heating feed temperature for the corresponding outside 
temperature must be set on the weather compensator. 
This setting must not be greater than that required by 
the design of the heating installation.
The correct setting is normally undertaken by the 
heating engineer. Desired heating and set-back phases 
(e.g. at night) are automatically turned on and off by 
using integrated time programs.
Weather compensators combined with thermostat valves 
are the most economical form of heating regulation.

Reducing the heating system

Reducing the room temperature at night and in your 
absence. This is best and most reliably realised using 
regulators with customisable time programs.
At such times, set the room temperature approx. 5 °C 
lower than during full heating times. Reduction of more 
than 5 °C brings no additional energy saving, because 
then increased heating capacities would be needed for 
the next full heating period. Only for longer absences, 
e.g. holidays, is it worthwhile to further lower the 
temperatures. However, in winter, make sure that there 
is adequate frost protection.

Room temperature

Set the room temperature only as high as would be 
enough for your comfort level. An extra degree would 
mean increased energy consumption of about 6%.
Adjust the room temperature according to the purpose 
of use of the room. For example, normally, it is not 
required that bedrooms or seldom used rooms are 
heated to 20 °C.

Setting the operating mode

In warmer seasons, when the apartment needs no 
heating, turn the heating to summer mode. The heating 
mode is then shut off, however, the device or the plant 
remains ready for operation for water heating.

Uniform heating

Often, in an apartment with central heating, only one 
room is heated. Through the encapsulation surfaces of 
this room, i.e. walls, doors, windows, roofs, floors, the 
unheated adjoining rooms are also heated in an 
unregulated manner, i.e. unwanted heat energy is lost. 
The capacity of the radiator in this one heated room is 
obviously not enough for such an operating mode.
Consequently, the room can not be heated satisfactorily 
and an uncomfortable feeling of coolness prevails (the 
same effect is produced when doors between heated or 
unheated or slightly heated rooms remain open).
This is incorrect saving: The heating is in operation and 
still the room temperature is not comfortably warm. 
Increased levels of heating comfort and more effective 
operation are achieved if all rooms in an appartment are 
heated evenly and in accordance with their utilisation. 
The building structure can, by the way, also suffer if 
sections of the building are unheated or only partially 
heated.

Thermostat valves and room thermostat

It should be a matter of course, today, that all radiators 
be fitted with thermostatic valves. They exactly maintain 
the set room temperature. You can adjust the room 
temperature to suit your individual requirements and 
ensure effective operation of your heating installation 
using the thermostatic valves in combination with a 
room temperature regulator (weather compensator).
In the room where the room temperature regulator is 
located, all the radiator valves should be fully opened 
since otherwise the two regulating systems will work 
against each other and the regulation quality can be 
affected.
The following actions by the user are seen quite often: 
As soon as the temperature in the room gets too hot the 
thermostatic valves are turned down (or the room 
thermostat is set to a reduced temperature). If it gets 
too cold again after a time, the thermostatic valve is 
opened up again.
This is not necessary since the temperature regulation 
system takes over this task via the thermostatic valve: If 
the room temperature rises above the value set on the 
sensor head, the thermostat valve shuts off 
automatically, when the temperature drops below the 
defined value, it opens again.

Notes on the installation and operation 3

Summary of Contents for ecoCRAFT VKK GB 1206/2-E-H

Page 1: ...For the owner VKK GB 806 2 E H VKK GB 1206 2 E H VKK GB 1606 2 E H VKK GB 2006 2 E H VKK GB 2406 2 E H VKK GB 2806 2 E H Operating manual ecoCRAFT Modular Gas Condensing Boiler GB...

Page 2: ...e accept no liability for any damage caused by failure to observe these instructions Other applicable documents All operating manuals of structural parts and components of the installation must be obs...

Page 3: ...rations to structural elements in the vicinity of the appliance which might affect its operational safety For example Keep all openings for air and flue gas free Make sure for example that any tempora...

Page 4: ...ecoCRAFT units are state of the art appliances which have been constructed in accordance with recognised safety regulations Nevertheless there is still a risk of death or serious injury to the user o...

Page 5: ...to summer mode The heating mode is then shut off however the device or the plant remains ready for operation for water heating Uniform heating Often in an apartment with central heating only one room...

Page 6: ...mes can be set using timers which most circulation pumps have fitted to them or with which they can be retro fitted Weather compensators often have ancillary functions for controlling circulation pump...

Page 7: ...ult resolution see Chapter 5 1 9 Button for switching the unit on and off 4 3 Switching the unit on and off 1 Fig 4 2 Switching the unit on and off Caution The mains switch may only be actuated if the...

Page 8: ...operational condition of your unit The operation codes 1 2 and 5 appear at the start of each individual module The number of the individual module is preset on the operational display The following di...

Page 9: ...ory setting max Call ups and settings Setting Display Store set value with OK Factorysettingmaynot bechanged Operation mode ParameterNo ParameterNo ParameterNo Factorysettingmaynot bechanged Hotwater...

Page 10: ...C in the parameter level under point 3 Caution None of the other settings in the parameter level can be changed to avoid malfunctions 4 6 Diagnosis mode In the diagnosis mode you can have the individu...

Page 11: ...fault resolution button 1 on the operating field The faults on the boiler can be resolved as follows First reset the relevant module by pushing the corresponding red module reset button 1 on the opera...

Page 12: ...itch integrated in the unit which prevents the unit from starting up if the system pressure 0 2 bar This is shown in the display as E26 At water pressures 0 8 bar the fault display disappears If the h...

Page 13: ...peration of your boiler it is recommended that regular servicing is carried out by your service provider Vaillant Applied System Sales Vaillant Ltd Unit D1 Lowfields Business Park Elland West Yorkshir...

Page 14: ......

Page 15: ......

Page 16: ...0020029295_00 GB 07 2006...

Reviews: