Vaillant ecoCRAFT VKK GB 1206/2-E-H Operating Manual Download Page 4

4

Operating manual

 ecoCRAFT 

Filling pressure of the heating system

The filling pressure of the heating installation should be 
checked at regular intervals.

Emergency power supply

Your specialist technician connected your gas heating 
boiler to the electrical mains during installation.
If you wish to keep the unit running with an emergency 
power supply in the event of a power failure, the 
technical specification of the unit (frequency, voltage, 
earthing) must be in agreement with the mains power 
supply, and must be rated to at least the power 
consumption of your unit. Please consult your heating 
engineer on this subject.

Frost protection

If you are going to be away during a cold period, make 
sure the heating system remains in operation and that 
the rooms are sufficiently heated.

 Caution!

The frost protection and monitoring devices are 
only active if the mains switch of the unit is 
depressed and shows a green light.
Addition of frost preventative medium to the 
heating water is not permitted. Otherwise it 
could result in damage to seals and diaphragms 
as well as to noises in the heating operation. 
Vaillant assumes no liability for this and such 
consequential damages.

Your unit has a frost protection function: If the heating 
flow temperature falls below 10°C with the main switch 
turned on, the appliance starts up and heats the entire 
heating circuit to approx. 20 °C.

 Caution!

Through-flow of the entire heating installation 
cannot be guaranteed.

Another way to protect the heating system and the 
appliance from frost is to drain them. You must ensure 
that the system and the appliance are completely 
drained. 
Contact your heating engineer.

Notes on the installation and 
operation

3.1 Intended 

use

The Valliant ecoCRAFT units are state-of-the-art 
appliances which have been constructed in accordance 
with recognised safety regulations. Nevertheless, there 
is still a risk of death or serious injury to the user or 
others or of damage to the device and other property in 
the event of improper use or use for which it is not 
intended.
The units are intended as heat generators for hot water 
- central heating installations. Any other use or extended 
use is considered to be improper. The manufacturer or 
supplier is not liable for any resulting damage. The user 
alone bears the risk.
Intended use includes the observance of the operating 
and installation manual and all other applicable 
documents, as well as adherence to the maintenance 
and inspection conditions.

 Caution!

Any improper use is forbidden.

The appliances must be installed by a heating engineer, 
who is responsible for adhering to the existing 
regulations, rules and guidelines.

3.2 

Requirements of the installation site

The Vaillant gas heating boilers ecoCRAFT must be 
installed in boiler rooms. Ask your heating engineer 
which national regulations must be observed.
The entire installation site should be frost-proof. 
Observe the specified frost protection measures in 
Chapter 2 if you are unable to ensure this requirement.

 Note!

It is not necessary to keep a clearance between 
the appliance and combustible materials or 
components, since at the rated heating power 
of the appliance the temperature at the surface 
of the housing is always lower than the 
maximum allowed temperature of 85 °C.

When installing the unit, the recommended minimum 
distances given in the maintenance manual should be 
observed for reasons of accessibility.

3.3 Care

• Clean the exterior of your appliance with a damp cloth 
and a little soap.

 Note!

Do not use scouring or cleaning agents, which 
may damage the housing or plastic fittings.

2 Safety instructions
3 Notes on the installation and operation

Summary of Contents for ecoCRAFT VKK GB 1206/2-E-H

Page 1: ...For the owner VKK GB 806 2 E H VKK GB 1206 2 E H VKK GB 1606 2 E H VKK GB 2006 2 E H VKK GB 2406 2 E H VKK GB 2806 2 E H Operating manual ecoCRAFT Modular Gas Condensing Boiler GB...

Page 2: ...e accept no liability for any damage caused by failure to observe these instructions Other applicable documents All operating manuals of structural parts and components of the installation must be obs...

Page 3: ...rations to structural elements in the vicinity of the appliance which might affect its operational safety For example Keep all openings for air and flue gas free Make sure for example that any tempora...

Page 4: ...ecoCRAFT units are state of the art appliances which have been constructed in accordance with recognised safety regulations Nevertheless there is still a risk of death or serious injury to the user o...

Page 5: ...to summer mode The heating mode is then shut off however the device or the plant remains ready for operation for water heating Uniform heating Often in an apartment with central heating only one room...

Page 6: ...mes can be set using timers which most circulation pumps have fitted to them or with which they can be retro fitted Weather compensators often have ancillary functions for controlling circulation pump...

Page 7: ...ult resolution see Chapter 5 1 9 Button for switching the unit on and off 4 3 Switching the unit on and off 1 Fig 4 2 Switching the unit on and off Caution The mains switch may only be actuated if the...

Page 8: ...operational condition of your unit The operation codes 1 2 and 5 appear at the start of each individual module The number of the individual module is preset on the operational display The following di...

Page 9: ...ory setting max Call ups and settings Setting Display Store set value with OK Factorysettingmaynot bechanged Operation mode ParameterNo ParameterNo ParameterNo Factorysettingmaynot bechanged Hotwater...

Page 10: ...C in the parameter level under point 3 Caution None of the other settings in the parameter level can be changed to avoid malfunctions 4 6 Diagnosis mode In the diagnosis mode you can have the individu...

Page 11: ...fault resolution button 1 on the operating field The faults on the boiler can be resolved as follows First reset the relevant module by pushing the corresponding red module reset button 1 on the opera...

Page 12: ...itch integrated in the unit which prevents the unit from starting up if the system pressure 0 2 bar This is shown in the display as E26 At water pressures 0 8 bar the fault display disappears If the h...

Page 13: ...peration of your boiler it is recommended that regular servicing is carried out by your service provider Vaillant Applied System Sales Vaillant Ltd Unit D1 Lowfields Business Park Elland West Yorkshir...

Page 14: ......

Page 15: ......

Page 16: ...0020029295_00 GB 07 2006...

Reviews: