VAI 2-025 WNVAI 2-035 WNVAI 2-050 WNVAI 2-065 WNVAM 2-050 W2NVAM 2-060 W2NVAM 2-085 W3NVAM 2-085 W4NVAI 2-025 WVAI 2-035 WVAI 2-050 WVAM 2-060 W2
climaVAIR
DE, EN, HR, IT, TR
Page 1: ...VAI 2 025 WN VAI 2 035 WN VAI 2 050 WN VAI 2 065 WN VAM 2 050 W2N VAM 2 060 W2N VAM 2 085 W3N VAM 2 085 W4N VAI 2 025 W VAI 2 035 W VAI 2 050 W VAM 2 060 W2 climaVAIR DE EN HR IT TR...
Page 2: ......
Page 3: ...For the user User Manual Air Conditioner climaVAIR Split Type EN VAI2 VAM2...
Page 4: ...ating Mode HEAT 13 7 6 Setting the Airflow Direction 14 7 6 1 Vertical Airflow 14 7 7 Special Function Selection 14 7 7 1 Health Anion Operation ION 14 7 7 2 SLEEP Function 15 7 7 3 TIMER ON OFF Funct...
Page 5: ...g the air conditioning Note Keep the manuals throughout the service life of the unit Note The information relating to this unit is divided between two manuals installation manual and user manual Note...
Page 6: ...ised of the following elements Outdoor unit Indoor unit Remote controller Interconnecting services Supplied accessories Figure 5 1 shows the unit components Fig 5 1 Unit components Legend 1 Indoor Uni...
Page 7: ...city Anti bacterial filter Filter with an anti allergenic and anti bacterial effect which keeps the atmosphere clean and healthy Anti dust filter General filter which eliminates much of the dirt and d...
Page 8: ...osition a few minutes later Remove the batteries in case the air conditioning is out of use for a long period If there is anything still showing on display just press the reset button Warning Danger o...
Page 9: ...the air conditioning unit by pulling the cord Danger of injury and physical damage Danger of fire and explosion Damaged air conditioners should not be put into operation In case of doubt consult your...
Page 10: ...on 7 CLOCK button 8 TIMER button 9 ION button 10 DEL button 11 FAN button 12 TURBO FP button 13 LIGHT LOCK button 14 FOLLOW ME button 7 2 2 Display Indicators Fig 7 2 Overview of the indicators Legend...
Page 11: ...button for less than 2 seconds to light the display of the Indoor Unit To switch the display back off press the LIGHT LOCK button for less than 2 seconds once again 7 4 Turning the unit on and off In...
Page 12: ...activate With the unit connected see section 7 4 Press the MODE button The different operation modes are displayed Fig 7 6 Operation modes Select the cooling operation mode COOL Press the TEMP TIME b...
Page 13: ...n modes are displayed Fig 7 9 Operation modes Select the dehumidifying mode DRY Press the TEMP TIME buttons to select the temperature setting When pressing the TEMP TIME buttons the temperature config...
Page 14: ...Fan selection mode Legend 1 MODE button 2 FAN mode indicator 3 FAN button In order to activate the fan mode FAN With the unit connected see section 7 4 Press the MODE button The different operation mo...
Page 15: ...ig 7 16 Operation modes Select the heating operation mode HEAT Press the TEMP TIME buttons to select the temperature setting When pressing the TEMP TIME buttons the temperature configuration will incr...
Page 16: ...button to direct the airflow upwards or downwards Once pressing air deflector will turn 6 degrees When pressing for over 3 seconds the vertical airflow enters AUTO mode 7 7 Special Function Selection...
Page 17: ...ve the configured temperature Once an hour has elapsed the temperature will rise 1 C more The unit is operational for 7 hours before stopping In HEAT mode The ambient temperature decreases 2 C in rela...
Page 18: ...previous steps successively When pressing the TEMP TIME buttons the time configuration will increase or decrease by 10 minutes If the TEMP TIME buttons are kept pressed the time will increase or decr...
Page 19: ...en activated the remote control display shows the actual temperature at its location The remote control will send this infor mation to the indoor unit every 3 minutes so the tem perature at the locati...
Page 20: ...ncy Operation Only use this function when the remote controller is broken or has been mislaid In order to activate Press the emergency operation switch A beeping noise is heard which indicates that th...
Page 21: ...s windows ceiling and floor the adjacent rooms are cooler than the room temperature therefore thermal energy is unintentionally lost It is therefore difficult to adequately heat the room and an unplea...
Page 22: ...ing mode or excessively low temperature in heating mode Set the temperature properly Obstacle in front of the air inlet or outlet Remove the obstacle to allow the air to circulate properly The ambient...
Page 23: ...them with cold water Ensure that the filters are dried completely dry in the shade before putting them back into the unit The activated carbon filters where fitted can be reactivated by placing in dir...
Page 24: ...the product ensure that is done safely and in accordance with local by laws and reulations In order to do so follow the steps described in the installation manual in reverse order and use the necessa...
Page 25: ...r Vaillant si riserva il diritto di apportare modifiche senza preavviso Vaillant pridr ava pravo na izmjene bez najave Vaillant reserves the right to add modifications without prior notice Vaillant be...
Page 26: ...illant hr Vaillant S p A 20159 Milano Via Benigno Crespi 70 Telefono 02 69 21 71 Telefax 02 69 71 22 00 www vaillant it info italia vaillant de Vaillant Ltd Nottingham Road Belper Derbyshire DE56 1JT...